ASUS Vivo AiO V241EA-DB003 all-in-one PC 23.8" Intel Pentium Gold 7505 8GB DDR4 512GB
- Windows 10 Home 🙋♀…
- Intel Pentium Gold…
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
DELL
1U rack server holds four 3.5" SATA drives and runs a 12-core Xeon Silver 4510 at 2.4 GHz with 24 threads and 30 MB cache
The Dell PowerEdge R660xs is a 1U rack server configured with one Intel Xeon Silver 4510 processor running at 2.4 GHz with 12 cores and 24 threads. It targets environments that need compute density without a second CPU, such as web hosting, virtualisation clusters or departmental databases. Buyers who require dual-socket scale or more than four drive bays should look elsewhere.
A dedicated heatsink handles the 150 W TDP of the single Xeon Silver 4510, while Dell Active Power Controller adjusts power draw to match workload demand. The 1U chassis uses high-speed fans that ramp with inlet temperature, so acoustic output rises under sustained load. Typical operation stays within the thermal envelope defined for the 150 W CPU limit.
The 3.5-inch chassis holds up to four SATA hard drives and uses embedded SATA without a hardware RAID controller, so data protection relies on software RAID or external solutions. Memory runs at 5600 MT/s using DDR5 RDIMMs, and the system boots in UEFI mode with GPT partitioning. Single-CPU layout leaves the second socket empty, limiting future expansion to storage only.
| Brand | DELL |
|---|---|
| Model | QUO-25458444-F6W4Z1 |
| Part Number | QUO-25458444-F6W4Z1 |
| Forsendelsesvægt | 13.61 kg |
| Pakkestørrelse | 762 × 508 × 508 mm |
Align the processor with the socket keying, lower the load plate, then torque the heatsink screws in a diagonal pattern to 11 in-lb; the step most often missed is the diagonal torque sequence.
Plan to replace SATA drives after five years or when SMART alerts appear, and reseat DDR5 modules if correctable ECC errors rise above the platform threshold.
The 150W heatsink reaches its thermal capacity before the power supply or memory bandwidth becomes a bottleneck.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ingen sprog matcher.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?