Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

MINUTEMAN

MINUTEMAN RPM208I2LCD-HW 8-Outlet Switched PDU Hardwired 20A 0U Vertical

SKU CH-87D0-00XX7 MPN RPM208I2LCD-HW

A hardwired 20 A vertical PDU with eight switched outlets, built-in web server, SNMP and LCD read-outs for remote power management

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)Hardwire
  • Cord Length10 ft
  • Hardwired 20 A input suits permanent rack installations
  • Eight individually switched outlets enable remote power cycling per device
  • 0U vertical form factor preserves horizontal rack space
  • Built-in LCD shows real-time amps, temperature and IP address
  • IP-addressable management with SNMP, email alerts and web interface

Hardwired Switched PDU for 20 A Vertical Racks

The Minuteman RPM208I2LCD-HW is a new 0U vertical power distribution unit designed for rack environments. It accepts a 20 A hardwired feed through a 10 ft cord and provides eight switched outlets. An integrated LCD shows real-time amperage, IP address, temperature and humidity readings.

Suited for Admins Who Need Per-Outlet IP Control

Network managers can power-cycle individual devices, set sequencing delays and receive email or SNMP alerts from a single IP address. The unit supports IPv4, IPv6, SNMP v1/v2c/v3, SSH and RADIUS authentication. Builders who require plug-in input connectors or outlet-level metering should evaluate other form factors.

20 A Hardwired Input with Circuit-Breaker Protection

The single decisive specification is the 20 A hardwired input paired with an input circuit breaker. This combination fixes the maximum usable current and the installation method, determining whether the PDU matches the site wiring and breaker panel.

Helstu kostir

  • Hardwired 20 A input suits permanent rack installations
  • Eight individually switched outlets enable remote power cycling per device
  • 0U vertical form factor preserves horizontal rack space
  • Built-in LCD shows real-time amps, temperature and IP address
  • IP-addressable management with SNMP, email alerts and web interface

Tæknilýsing

BrandMINUTEMAN
ModelRPM208I2LCD-HW
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)Hardwire
Cord Length10 ft
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Sendingarþyngd3.18 kg
Stærð sendingar505 × 211 × 89 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What is the maximum sustained current the PDU can deliver before the input circuit breaker trips?

The unit is rated for a maximum output current of 20 A and is protected by an input circuit breaker that will open if that limit is exceeded.

How much heat or noise does the unit generate during continuous operation?

The specifications list no fan or acoustic rating; the PDU is a passive distribution device with an LCD display and network interface, so heat and noise are minimal.

What network connection must already exist in the rack for the PDU to be managed remotely?

A 10/100 Base-T Ethernet port with a CAT5 cable is required to connect the built-in web server and SNMP interface to the management network.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.