Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

MINUTEMAN

MINUTEMAN RPM204I2LCD-HW Switched PDU 4×C13 Hardwired 20A 10ft 0U LCD

SKU CH-6V1X-7KJSE MPN RPM204I2LCD-HW

Switched PDU with four C13 outlets, hardwired 20 A input, 10 ft cord, local LCD and IP-addressable remote power management

  • TypePower Distribution Units
  • StyleHorizontal Installation, 0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)Hardwire
  • Cord Length10 ft
  • Remote reboot via IP-addressable switched outlets
  • Local LCD shows amps, IP, temperature, humidity
  • Hardwired 20 A input with 10 ft cord
  • Four rear C13 receptacles with circuit-breaker protection
  • 5 000-entry power and event logs via web/SNMP

Switched PDU with Hardwired Input

The Minuteman RPM204I2LCD-HW is a switched power distribution unit designed for rack-mounted IT equipment. It provides four IEC C13 outlets fed by a hardwired 20A input with a 10 ft cord. The unit supports both horizontal and 0U vertical mounting styles and includes an input circuit breaker for overload protection.

For Network Admins Needing Remote Outlet Control

This PDU suits administrators who require IP-addressable remote power cycling and real-time monitoring of current, temperature, or humidity via the built-in LCD. It is not for environments that need more than four outlets, plug-and-play input connections, or outlet-level power metering beyond the aggregate 20A reading.

Check Rack Space and Hardwire Provision

Verify that your rack can accommodate horizontal or 0U vertical mounting and that a qualified electrician can terminate the hardwired 20A feed to local code. Confirm the four C13 outlets match your device power cords and that your network infrastructure supports 10/100 Base-T Ethernet for the management interface.

Helstu kostir

  • Remote reboot via IP-addressable switched outlets
  • Local LCD shows amps, IP, temperature, humidity
  • Hardwired 20 A input with 10 ft cord
  • Four rear C13 receptacles with circuit-breaker protection
  • 5 000-entry power and event logs via web/SNMP

Tæknilýsing

BrandMINUTEMAN
ModelRPM204I2LCD-HW
TypePower Distribution Units
StyleHorizontal Installation, 0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)Hardwire
Cord Length10 ft
Output Connector(s)Rear Panel Receptacles: (4) C13
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Sendingarþyngd2.27 kg
Stærð sendingar505 × 211 × 89 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What must already be in the rack for the hard-wired 20 A input to connect?

A dedicated 20 A circuit with suitable terminals is required; the 10 ft lead is hard-wired directly to that supply.

Can the four C13 outlets power legacy servers that only draw a few amps each?

Yes, each C13 receptacle shares the 20 A total capacity, so low-draw legacy gear works as long as combined load stays within the breaker limit.

How do I confirm the PDU is operating correctly after installation?

The front LCD shows real-time amps, IP address, temperature and humidity, while the web interface logs power data and events for verification.