Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

MINUTEMAN

MINUTEMAN RPM204I2LCD-HW Switched PDU 4×C13 Hardwired 20A 10ft 0U LCD

SKU CH-6V1X-7KJSE MPN RPM204I2LCD-HW

Switched PDU with four C13 outlets, hardwired 20 A input, 10 ft cord, local LCD and IP-addressable remote power management

  • TypePower Distribution Units
  • StyleHorizontal Installation, 0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)Hardwire
  • Cord Length10 ft
  • Remote reboot via IP-addressable switched outlets
  • Local LCD shows amps, IP, temperature, humidity
  • Hardwired 20 A input with 10 ft cord
  • Four rear C13 receptacles with circuit-breaker protection
  • 5 000-entry power and event logs via web/SNMP

Switched PDU with Hardwired Input

The Minuteman RPM204I2LCD-HW is a switched power distribution unit designed for rack-mounted IT equipment. It provides four IEC C13 outlets fed by a hardwired 20A input with a 10 ft cord. The unit supports both horizontal and 0U vertical mounting styles and includes an input circuit breaker for overload protection.

For Network Admins Needing Remote Outlet Control

This PDU suits administrators who require IP-addressable remote power cycling and real-time monitoring of current, temperature, or humidity via the built-in LCD. It is not for environments that need more than four outlets, plug-and-play input connections, or outlet-level power metering beyond the aggregate 20A reading.

Check Rack Space and Hardwire Provision

Verify that your rack can accommodate horizontal or 0U vertical mounting and that a qualified electrician can terminate the hardwired 20A feed to local code. Confirm the four C13 outlets match your device power cords and that your network infrastructure supports 10/100 Base-T Ethernet for the management interface.

Puncte forte

  • Remote reboot via IP-addressable switched outlets
  • Local LCD shows amps, IP, temperature, humidity
  • Hardwired 20 A input with 10 ft cord
  • Four rear C13 receptacles with circuit-breaker protection
  • 5 000-entry power and event logs via web/SNMP

Specificații

BrandMINUTEMAN
ModelRPM204I2LCD-HW
TypePower Distribution Units
StyleHorizontal Installation, 0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)Hardwire
Cord Length10 ft
Output Connector(s)Rear Panel Receptacles: (4) C13
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Greutate la expediere2.27 kg
Dimensiunile coletului505 × 211 × 89 mm

Alte versiuni ale acestui model

5 în plus din aceeași gamă

Aceeași familie, memorie, radiator sau frecvență diferite — comparați înainte de a vă decide.

Întrebări despre acest articol

What must already be in the rack for the hard-wired 20 A input to connect?

A dedicated 20 A circuit with suitable terminals is required; the 10 ft lead is hard-wired directly to that supply.

Can the four C13 outlets power legacy servers that only draw a few amps each?

Yes, each C13 receptacle shares the 20 A total capacity, so low-draw legacy gear works as long as combined load stays within the breaker limit.

How do I confirm the PDU is operating correctly after installation?

The front LCD shows real-time amps, IP address, temperature and humidity, while the web interface logs power data and events for verification.