Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

MINUTEMAN

MINUTEMAN RPM2024I2LCD-L20P PDU 24-Outlet Switched NEMA L6-20P 21×C13 3×C19 0U Vertical

SKU CH-8MCF-B732M MPN RPM2024I2LCD-L20P

A 24-outlet switched PDU with 21 C13 and 3 C19 receptacles, NEMA L6-20P input, 10 ft cord, and IP-addressable remote management via web, SNMP, and LCD display

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)NEMA L6-20P
  • Cord Length10 ft
  • Remote outlet control via IP-addressable switched PDU
  • 24 total outlets: 21 C13 and 3 C19 receptacles
  • 0U vertical design saves rack space
  • Local LCD shows amps, IP, temperature and humidity
  • 62368-1 certified with 20 A circuit-breaker protection

Switched 0U Vertical PDU

The MINUTEMAN RPM2024I2LCD-L20P is a 24-outlet switched power distribution unit designed for 0U vertical rack mounting. It accepts a NEMA L6-20P input plug rated for 20 A and provides twenty-one IEC 60320 C13 and three IEC 60320 C19 receptacles. A 10 ft cord connects the unit to the power source. Built-in LCD readouts show current draw, IP address, temperature and humidity.

Remote Management Capabilities

Network administrators can control each outlet individually through a built-in web server, SNMP v1/v2c/v3, SSH or Telnet. The PDU supports IPv4 and IPv6, RADIUS authentication and role-based user accounts. Event notifications are delivered via email, SNMP traps, syslog or audible alarm. Firmware upgrades are performed remotely. This unit suits teams needing per-outlet switching and environmental monitoring from a single IP address.

Input Circuit Breaker Protection

Overload protection is provided by an input circuit breaker rated at 20 A. The breaker trips when total connected load exceeds this limit, protecting both the PDU and upstream wiring. Buyers whose rack gear demands more than 20 A aggregate must look at higher-rated power distribution. The 62368-1 certification confirms compliance with applicable safety standards.

Puncte forte

  • Remote outlet control via IP-addressable switched PDU
  • 24 total outlets: 21 C13 and 3 C19 receptacles
  • 0U vertical design saves rack space
  • Local LCD shows amps, IP, temperature and humidity
  • 62368-1 certified with 20 A circuit-breaker protection

Specificații

BrandMINUTEMAN
ModelRPM2024I2LCD-L20P
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)NEMA L6-20P
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (21) C13 / (3) C19
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Greutate la expediere8.62 kg
Dimensiunile coletului1890 × 221 × 109 mm

Alte versiuni ale acestui model

5 în plus din aceeași gamă

Aceeași familie, memorie, radiator sau frecvență diferite — comparați înainte de a vă decide.

Întrebări despre acest articol

What happens when the 20 A input circuit breaker trips during sustained load?

The input circuit breaker cuts power to all 24 outlets until it is manually reset, protecting the PDU and connected equipment from overload.

Does the LCD stay on continuously and add audible noise in a 0U vertical rack?

The local LCD shows amps, IP address, temperature and humidity with no moving parts, so it adds no fan noise and negligible heat.

Which network cable and IP scheme are required for the built-in web server?

A standard CAT5 cable connects the 10/100 Base-T Ethernet port, and the PDU supports both IPv4 and IPv6 addressing.

Tot din acest raion

Clienții au comparat și acestea.

Același raion, aceeași finalizare a comenzii — opt monede și un curs blocat 30 de minute.