Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

MINUTEMAN

MINUTEMAN RPM2016N1LCD-L20P PDU 16-Outlet Switched NEMA L5-20P 0U Vertical

SKU CH-3PZY-7QJ0D MPN RPM2016N1LCD-L20P

A switched PDU with 16 NEMA 5-15/20R outlets, NEMA L5-20P input, 0U vertical mounting and an LCD for local monitoring

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)NEMA 5-L20P
  • Cord Length10 ft
  • Switched control of 16 outlets from a single IP address
  • Local LCD shows real-time amps, IP, temperature and humidity
  • 62368-1 certified with 20 A circuit-breaker overload protection
  • 10 ft NEMA L5-20P cord powers vertical 0U rack installation
  • Email or SNMP alerts plus daily, weekly, monthly, yearly power logs

Switched 16-outlet PDU for rack power control

The Minuteman RPM2016N1LCD-L20P is a 0U vertical power distribution unit that fits along the side of a standard rack. It delivers 16 front-panel NEMA 5-15/20R outlets from a single NEMA L5-20P input with a 10 ft cord. A built-in web server and SNMP support let administrators switch each outlet on or off, reboot attached gear, and monitor load, temperature and humidity from the local LCD or over the network.

Remote managers who need per-outlet switching

This unit suits network operators who want IP-addressable control of up to 16 devices, event notifications by email or SNMP traps, and power sequencing from one IP address. It also supports centralized monitoring software for larger deployments. Buyers who only need basic power distribution without remote switching, or who require more than 16 outlets from a single PDU, should consider other models.

Verify rack space, input plug and circuit capacity

Confirm the rack has 0U vertical mounting clearance along the side rails. Ensure the facility can provide a NEMA L5-20P receptacle on a 20 A branch circuit, as the PDU draws up to 20 A and protects the input with a built-in circuit breaker. Check that the 10 ft input cord reaches the power source without strain.

Puncte forte

  • Switched control of 16 outlets from a single IP address
  • Local LCD shows real-time amps, IP, temperature and humidity
  • 62368-1 certified with 20 A circuit-breaker overload protection
  • 10 ft NEMA L5-20P cord powers vertical 0U rack installation
  • Email or SNMP alerts plus daily, weekly, monthly, yearly power logs

Specificații

BrandMINUTEMAN
ModelRPM2016N1LCD-L20P
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)NEMA 5-L20P
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15/20R
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Greutate la expediere5.44 kg
Dimensiunile coletului1359 × 221 × 109 mm

Alte versiuni ale acestui model

5 în plus din aceeași gamă

Aceeași familie, memorie, radiator sau frecvență diferite — comparați înainte de a vă decide.

Întrebări despre acest articol

What type of input receptacle must already be on the circuit to plug in the NEMA L5-20P cord?

The PDU ships with a 10 ft cord ending in a NEMA L5-20P locking plug, so the building circuit must provide a matching NEMA L5-20R receptacle rated for 20 A

Will the sixteen 5-15/20R outlets accept both standard 5-15 plugs and 5-20 locking plugs from older equipment?

Each front-panel receptacle is a 5-15/20R hybrid that accepts either a standard NEMA 5-15 plug or a NEMA 5-20 plug, so legacy gear with either plug style connects directly

How can I confirm the PDU is powered and reachable on the network after mounting it vertically?

The built-in LCD shows real-time amps, the assigned IP address, and temperature or humidity readings, while the 10/100 Base-T Ethernet port links to the network for web, SNMP or SSH access

Tot din acest raion

Clienții au comparat și acestea.

Același raion, aceeași finalizare a comenzii — opt monede și un curs blocat 30 de minute.