Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

MINUTEMAN

MINUTEMAN RPM3024I2LCD-HW PDU Switched Hardwired 21 C13 3 C19 0U Vertical 208V 30A

SKU CH-1KAE-SAT79 MPN RPM3024I2LCD-HW

A switched 0U vertical PDU with 21 C13 and 3 C19 outlets, hardwired 208 V 30 A input, and IP-addressable remote management via web browser or SNMP

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Input Voltage208V
  • Maximum Input Current30A
  • Input Connector(s)Hardwire
  • Remote power control via IP-addressable management
  • 24 switched outlets (21 C13, 3 C19) for dense deployments
  • Local LCD shows amps, IP, temperature and humidity
  • 208V 30A hardwired input with circuit-breaker protection
  • 62368-1 certified, 0U vertical rack-mount with 10 ft cord

Switched PDU for 208 V 30 A Racks

This switched power distribution unit delivers 208 V at up to 30 A through twenty-four locking IEC outlets. Network administrators gain remote on/off control and real-time monitoring for each connected device from a single IP address.

Hardwired Input with Vertical 0U Mounting

A 10 ft hardwire whip feeds the unit, which mounts vertically in a 0U orientation to preserve rack space. Twenty-one C13 and three C19 receptacles support mixed-density server and networking gear, while an input circuit breaker provides overload protection.

IP-Addressable Management with Local LCD

The built-in web server enables browser-based outlet switching, power sequencing, and threshold alerts via email or SNMP traps. A front-panel LCD reports current draw, IP address, and environmental data, and logs store up to 5,000 entries each for power history and events.

Puncte forte

  • Remote power control via IP-addressable management
  • 24 switched outlets (21 C13, 3 C19) for dense deployments
  • Local LCD shows amps, IP, temperature and humidity
  • 208V 30A hardwired input with circuit-breaker protection
  • 62368-1 certified, 0U vertical rack-mount with 10 ft cord

Specificații

BrandMINUTEMAN
ModelRPM3024I2LCD-HW
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Input Voltage208V
Maximum Input Current30A
Input Connector(s)Hardwire
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (21) C13 / (3) C19
Maximum Output Current30A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Greutate la expediere9.07 kg
Dimensiunile coletului1890 × 221 × 109 mm

Alte versiuni ale acestui model

5 în plus din aceeași gamă

Aceeași familie, memorie, radiator sau frecvență diferite — comparați înainte de a vă decide.

Întrebări despre acest articol

What network interface does the RPM3024I2LCD-HW use for remote management, and what speed does it run at?

The unit connects through a 10/100 Base-T Ethernet port, so remote monitoring and outlet control are limited to 100 Mbps.

What mounting orientation and rack space does the 0U vertical design require?

It mounts vertically along the side of a standard rack using 0U brackets, consuming no horizontal rack units.

How is the PDU powered, and which wiring step is often missed?

Input is hardwired through a 10 ft cord; the step often missed is landing the three conductors on a 30 A, 208 V branch circuit breaker before energising.

Tot din acest raion

Clienții au comparat și acestea.

Același raion, aceeași finalizare a comenzii — opt monede și un curs blocat 30 de minute.