BFKK 3U Rackmount Server Chassis EATX/ATX/MATX 4x5.25 6x3.5 Top/Side Cooling
- Rackmount
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
myVolts
A 24 V, 15 A switch-mode power supply with overload, over-voltage and short-circuit protection for industrial and radio equipment
This pink aluminium-cased unit delivers 360W of regulated DC power from AC110V or AC220V mains with a ±15% tolerance. It is aimed at engineers and hobbyists running industrial automation, LED displays, CCTV, 3D printers or radio equipment that require a steady 24V rail. The built-in voltage-adjust terminal allows fine tuning of the output to suit specific load requirements.
The supply operates from 0°C to 40°C ambient and is rated for up to 95% non-condensing humidity, relying on natural convection through the aluminium housing rather than a fan. Overload, over-voltage and short-circuit protection circuits shut the output down safely when limits are exceeded, and a 100% full-load burn-in at the factory verifies long-term reliability. Low DC ripple and high working efficiency keep waste heat low during continuous operation.
Screw terminals labelled L and N accept the AC input, while GND and V provide the DC output; an additional ADJ terminal gives access to the voltage adjustment. The compact footprint of approximately 85mm by 58mm by 33mm leaves room in tight enclosures and the lightweight aluminium chassis simplifies DIN-rail or panel mounting. CCC, FCC and CE markings confirm compliance for use in commercial and industrial installations.
| Type | AT |
|---|
Connect live and neutral to L and N for AC 110 or 220 V input; link GND to the negative DC rail and V to the positive 24 V rail — the ADJ terminal is only for voltage trim and is frequently mistaken for a second output
No scheduled servicing is required; the aluminium chassis relies on natural convection, so keep the vents clear of dust and verify the fan-less cooling path remains unobstructed
The rated operating range tops out at 40 °C; above that the internal protection will curtail output to prevent overheating
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Ekkert tungumál fannst.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?