Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
myVolts
A 24 V, 15 A switch-mode power supply with overload, over-voltage and short-circuit protection for industrial and radio equipment
This pink aluminium-cased unit delivers 360W of regulated DC power from AC110V or AC220V mains with a ±15% tolerance. It is aimed at engineers and hobbyists running industrial automation, LED displays, CCTV, 3D printers or radio equipment that require a steady 24V rail. The built-in voltage-adjust terminal allows fine tuning of the output to suit specific load requirements.
The supply operates from 0°C to 40°C ambient and is rated for up to 95% non-condensing humidity, relying on natural convection through the aluminium housing rather than a fan. Overload, over-voltage and short-circuit protection circuits shut the output down safely when limits are exceeded, and a 100% full-load burn-in at the factory verifies long-term reliability. Low DC ripple and high working efficiency keep waste heat low during continuous operation.
Screw terminals labelled L and N accept the AC input, while GND and V provide the DC output; an additional ADJ terminal gives access to the voltage adjustment. The compact footprint of approximately 85mm by 58mm by 33mm leaves room in tight enclosures and the lightweight aluminium chassis simplifies DIN-rail or panel mounting. CCC, FCC and CE markings confirm compliance for use in commercial and industrial installations.
| Type | AT |
|---|
Connect live and neutral to L and N for AC 110 or 220 V input; link GND to the negative DC rail and V to the positive 24 V rail — the ADJ terminal is only for voltage trim and is frequently mistaken for a second output
No scheduled servicing is required; the aluminium chassis relies on natural convection, so keep the vents clear of dust and verify the fan-less cooling path remains unobstructed
The rated operating range tops out at 40 °C; above that the internal protection will curtail output to prevent overheating
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Ni ustreznega jezika.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?