NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.
myVolts
Converts AC 110-265 V to regulated DC 12 V at 20 A with overload, over-voltage and short-circuit protection for CCTV cameras and LED strips
This regulated power supply converts AC mains between 110 V and 265 V into a stable DC 12 V output at up to 20 A. It is built for professional installations such as LED lighting strips, CCTV cameras and security surveillance systems. Overload, over-voltage and short-circuit protections are integrated, and cooling is handled by free convection.
The unit suits electricians and system integrators who need a compact, wide-input supply for 3528, 2835, 3014, 5050, 5630 or 5730 LED strips and IP cameras. It is not intended for applications requiring adjustable voltage rails, higher current than 20 A, or voltages other than 12 V DC. Buyers needing multiple isolated outputs or rack-mount form factors should look elsewhere.
The single specification that decides fit is the fixed 12 V DC output rated at 20 A with overload, over-voltage and short-circuit protection. The supply accepts 110–265 V AC at 50/60 Hz, operates from 0 °C to 40 °C and weighs approximately 645 g. Connection terminals are L and N for AC input, GND for DC negative and V for DC positive, with an ADJ point for fine voltage adjustment.
| Type | AT |
|---|
The unit has L and N terminals for AC input, GND for DC negative, V for DC positive, and an +V/ADJ terminal for output-voltage adjustment.
Wire live and neutral to L and N, connect the load to V+ and GND, then verify the ADJ setting before powering on — skipping the voltage check is the common error.
It operates at 0 to 40 °C with up to 95 % non-condensing humidity, includes overload, over-voltage and short-circuit protection, and should be replaced if protection trips repeatedly or output drifts outside 12 V.
Arī šajā sadaļā
Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.
Kriptovalūta, kurā maksājat, un valūta, kurā redzat cenas.
Nosūtīts no Jūsu maciņa, noformējot pasūtījumu
Tikai informatīvi — katalogā cenas norādītas ASV dolāros
Neviena valūta neatbilst.
Izvēlieties valodu, kurā vietne sarunājas ar Jums.
Pirmo reizi šeit?
Jau ir konts?
Automātiskas atiestatīšanas nav: šis veikals nesūta e-pastus, tāpēc nav arī vienreizējas saites, ko pieprasīt. Atstājiet adresi kontā, un tā tiks apstrādāta manuāli.
Pieprasījums saņemts
Uz Jūsu e-pastu nekas neatnāks — šis veikals vispār nesūta e-pastus. Kāds šos pieprasījumus apstrādā manuāli.
Atcerējāties?