NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Prijímame kryptomeny — takže mince, ktoré držíte, môžete zameniť za skutočný hardvér.Plaťte v krypte, miňte ho na skutočný hardvér. Poistená doprava zadarmo po celom svete nad 399 $. Neutrálne kartóny bez potlače, odosielané z Nemecka.Poistená doprava zadarmo nad 399 $. Váš kurz je zablokovaný na 30 minút hneď po otvorení pokladne.Kurz zablokovaný na 30 minút. Každý produkt je zapečatený, jeho sériové číslo je overené a vzťahuje sa naň 24-mesačná záruka.Zapečatené, 24-mesačná záruka.
myVolts
Converts AC 110-265 V to regulated DC 12 V at 20 A with overload, over-voltage and short-circuit protection for CCTV cameras and LED strips
This regulated power supply converts AC mains between 110 V and 265 V into a stable DC 12 V output at up to 20 A. It is built for professional installations such as LED lighting strips, CCTV cameras and security surveillance systems. Overload, over-voltage and short-circuit protections are integrated, and cooling is handled by free convection.
The unit suits electricians and system integrators who need a compact, wide-input supply for 3528, 2835, 3014, 5050, 5630 or 5730 LED strips and IP cameras. It is not intended for applications requiring adjustable voltage rails, higher current than 20 A, or voltages other than 12 V DC. Buyers needing multiple isolated outputs or rack-mount form factors should look elsewhere.
The single specification that decides fit is the fixed 12 V DC output rated at 20 A with overload, over-voltage and short-circuit protection. The supply accepts 110–265 V AC at 50/60 Hz, operates from 0 °C to 40 °C and weighs approximately 645 g. Connection terminals are L and N for AC input, GND for DC negative and V for DC positive, with an ADJ point for fine voltage adjustment.
| Type | AT |
|---|
The unit has L and N terminals for AC input, GND for DC negative, V for DC positive, and an +V/ADJ terminal for output-voltage adjustment.
Wire live and neutral to L and N, connect the load to V+ and GND, then verify the ADJ setting before powering on — skipping the voltage check is the common error.
It operates at 0 to 40 °C with up to 95 % non-condensing humidity, includes overload, over-voltage and short-circuit protection, and should be replaced if protection trips repeatedly or output drifts outside 12 V.
Aj v tomto oddelení
Rovnaké oddelenie, rovnaká pokladňa — osem mien a kurz zablokovaný na 30 minút.
Mena, v ktorej platíte, a mena, v ktorej sa zobrazujú ceny.
Odoslané z vašej peňaženky na pokladni
Len na zobrazenie — katalóg je uvedený v dolároch
Žiadna mena nezodpovedá.
Vyberte jazyk, v ktorom s vami bude web komunikovať.
Ste tu prvýkrát?
Účet už máte?
Automatický reset hesla neexistuje: tento obchod neposiela žiadne e-maily, takže neexistuje jednorazový odkaz, o ktorý by ste mohli požiadať. Nechajte adresu na účte — niekto sa jej ujme ručne.
Žiadosť zaznamenaná
Do vašej schránky nič nepríde — tento obchod neposiela vôbec žiadne e-maily. Niekto sa o to postará ručne.
Spomenuli ste si?