NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
myVolts
Converts AC 110-265 V to regulated DC 12 V at 20 A with overload, over-voltage and short-circuit protection for CCTV cameras and LED strips
This regulated power supply converts AC mains between 110 V and 265 V into a stable DC 12 V output at up to 20 A. It is built for professional installations such as LED lighting strips, CCTV cameras and security surveillance systems. Overload, over-voltage and short-circuit protections are integrated, and cooling is handled by free convection.
The unit suits electricians and system integrators who need a compact, wide-input supply for 3528, 2835, 3014, 5050, 5630 or 5730 LED strips and IP cameras. It is not intended for applications requiring adjustable voltage rails, higher current than 20 A, or voltages other than 12 V DC. Buyers needing multiple isolated outputs or rack-mount form factors should look elsewhere.
The single specification that decides fit is the fixed 12 V DC output rated at 20 A with overload, over-voltage and short-circuit protection. The supply accepts 110–265 V AC at 50/60 Hz, operates from 0 °C to 40 °C and weighs approximately 645 g. Connection terminals are L and N for AC input, GND for DC negative and V for DC positive, with an ADJ point for fine voltage adjustment.
| Type | AT |
|---|
The unit has L and N terminals for AC input, GND for DC negative, V for DC positive, and an +V/ADJ terminal for output-voltage adjustment.
Wire live and neutral to L and N, connect the load to V+ and GND, then verify the ADJ setting before powering on — skipping the voltage check is the common error.
It operates at 0 to 40 °C with up to 95 % non-condensing humidity, includes overload, over-voltage and short-circuit protection, and should be replaced if protection trips repeatedly or output drifts outside 12 V.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?