NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
myVolts
Converts AC 110-265 V to regulated DC 12 V at 20 A with overload, over-voltage and short-circuit protection for CCTV cameras and LED strips
This regulated power supply converts AC mains between 110 V and 265 V into a stable DC 12 V output at up to 20 A. It is built for professional installations such as LED lighting strips, CCTV cameras and security surveillance systems. Overload, over-voltage and short-circuit protections are integrated, and cooling is handled by free convection.
The unit suits electricians and system integrators who need a compact, wide-input supply for 3528, 2835, 3014, 5050, 5630 or 5730 LED strips and IP cameras. It is not intended for applications requiring adjustable voltage rails, higher current than 20 A, or voltages other than 12 V DC. Buyers needing multiple isolated outputs or rack-mount form factors should look elsewhere.
The single specification that decides fit is the fixed 12 V DC output rated at 20 A with overload, over-voltage and short-circuit protection. The supply accepts 110–265 V AC at 50/60 Hz, operates from 0 °C to 40 °C and weighs approximately 645 g. Connection terminals are L and N for AC input, GND for DC negative and V for DC positive, with an ADJ point for fine voltage adjustment.
| Type | AT |
|---|
The unit has L and N terminals for AC input, GND for DC negative, V for DC positive, and an +V/ADJ terminal for output-voltage adjustment.
Wire live and neutral to L and N, connect the load to V+ and GND, then verify the ADJ setting before powering on — skipping the voltage check is the common error.
It operates at 0 to 40 °C with up to 95 % non-condensing humidity, includes overload, over-voltage and short-circuit protection, and should be replaced if protection trips repeatedly or output drifts outside 12 V.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?