NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
HPE
External DC power supply for H3C S5500-52C-EI switch, delivering 12 V and 54 V redundant backup with cold-switching on power failure
The HPE RPS 800-A is an external redundant power supply designed for the H3C S5500-52C-EI switch. It accepts AC input and delivers selectable DC output to keep the switch running during an internal power supply failure. This unit suits network administrators who need cold-standby backup for a single compatible switch.
The supply provides +12 V DC, -54 V DC or both voltages simultaneously depending on which DC output cables are connected. It only activates its DC output when it detects a power supply failure in the powered device, so it does not share load during normal operation. Buyers who need active load-sharing or hot-swap redundancy cannot use this unit.
This RPS replaces a configuration with no external power redundancy for the S5500-52C-EI. The jump is worth it when downtime from a single internal supply failure is unacceptable and the switch chassis matches the listed compatibility. It does not support other switch models or higher-wattage requirements.
| Brand | HPE |
|---|---|
| Color | Multicolor |
| Type | Redundant Power Supply |
The RPS 800-A with part number JD183A is built for the H3C S5500-52C-EI, delivering selective +12 V and -54 V DC backup when the internal supply fails.
It indicates the maximum AC input capacity at 240 V; the RPS only activates its DC outputs (+12 V and -54 V) after detecting an internal power-supply failure in the switch.
It connects through dedicated DC output cables to the S5500-52C-EI, capping backup power to the switch's +12 V and -54 V rails and only engaging on internal supply failure.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?