HP ProDesk 600 G3 SFF all-in-one PC i7-6700 3.40GHz 32GB DDR4 2TB SSD Windows 10 Pro
- Business Desktops &…
- Slim/Small Form Fac…
Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
ICY DOCK
Six-bay U.2/U.3 NVMe enclosure fits a 5.25" bay, uses three SlimSAS 8i links for PCIe 4.0 at 64Gb/s per drive, and includes dual 40x20mm fans with EMI grounding
The ToughArmor MB118VP-B is a rugged six-bay enclosure that fits into any standard external 5.25" optical drive bay. It supports up to six U.2 or U.3 PCIe NVMe SSDs with a maximum drive height of 9.5 mm. Dual high-performance 40x20 mm cooling fans provide active airflow across all bays. EMI grounding protects installed SSDs from electrical damage.
This unit suits administrators who need hot-swap access to NVMe storage without opening a server chassis. Removable trays make drive replacement fast and tool-free. Builds that lack a free 5.25" front bay or that rely on internal M.2 slots cannot use this enclosure. Systems without a compatible PCIe 4.0 controller and three SlimSAS 8i (SFF-8654) host connections will not achieve full performance.
Each of the six drive bays delivers up to 64 Gb/s through a PCIe 4.0 x4 link. That bandwidth is the single figure that determines whether the enclosure matches your SSD and controller capabilities. If your host interface is limited to PCIe 3.0 x4 the drives will operate at half this throughput.
| Type | Rack |
|---|
The enclosure is built to the PCIe 4.0 spec and will negotiate down to PCIe 3.0 speeds when connected to a 3.0 controller, so your drives will operate at the lower link rate.
Listen for the fans at power-on and monitor each SSD temperature through your OS or RAID utility; steady readings under load show the airflow is working.
You receive the six-bay enclosure with its removable trays and dual fans installed; you must provide the U.2/U.3 NVMe SSDs and three SlimSAS 8i (SFF-8654) cables to connect to your controller.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?