HP ProDesk 600 G3 SFF all-in-one PC i7-6700 3.40GHz 32GB DDR4 2TB SSD Windows 10 Pro
- Business Desktops &…
- Slim/Small Form Fac…
Accettiamo criptovalute — così le crypto che Lei possiede possono comprare hardware reale.Paghi in crypto, la spenda in hardware reale. Spedizione assicurata gratuita in tutto il mondo oltre i 399 $. Cartoni neutri, senza marchio, spediti dalla Germania.Spedizione assicurata gratuita oltre i 399 $. Il Suo tasso resta bloccato per 30 minuti dall’apertura del checkout.Tasso bloccato 30 minuti. Ogni articolo è sigillato, il numero di serie è verificato, ed è coperto da una garanzia di 24 mesi.Sigillato, garantito 24 mesi.
ICY DOCK
Six-bay U.2/U.3 NVMe enclosure fits a 5.25" bay, uses three SlimSAS 8i links for PCIe 4.0 at 64Gb/s per drive, and includes dual 40x20mm fans with EMI grounding
The ToughArmor MB118VP-B is a rugged six-bay enclosure that fits into any standard external 5.25" optical drive bay. It supports up to six U.2 or U.3 PCIe NVMe SSDs with a maximum drive height of 9.5 mm. Dual high-performance 40x20 mm cooling fans provide active airflow across all bays. EMI grounding protects installed SSDs from electrical damage.
This unit suits administrators who need hot-swap access to NVMe storage without opening a server chassis. Removable trays make drive replacement fast and tool-free. Builds that lack a free 5.25" front bay or that rely on internal M.2 slots cannot use this enclosure. Systems without a compatible PCIe 4.0 controller and three SlimSAS 8i (SFF-8654) host connections will not achieve full performance.
Each of the six drive bays delivers up to 64 Gb/s through a PCIe 4.0 x4 link. That bandwidth is the single figure that determines whether the enclosure matches your SSD and controller capabilities. If your host interface is limited to PCIe 3.0 x4 the drives will operate at half this throughput.
| Type | Rack |
|---|
The enclosure is built to the PCIe 4.0 spec and will negotiate down to PCIe 3.0 speeds when connected to a 3.0 controller, so your drives will operate at the lower link rate.
Listen for the fans at power-on and monitor each SSD temperature through your OS or RAID utility; steady readings under load show the airflow is working.
You receive the six-bay enclosure with its removable trays and dual fans installed; you must provide the U.2/U.3 NVMe SSDs and three SlimSAS 8i (SFF-8654) cables to connect to your controller.
Anche in questo reparto
Stesso reparto, stessa cassa — otto monete e un cambio bloccato per 30 minuti.
Cosa invia per pagare, e in quale valuta legge i prezzi.
Inviato dal Suo portafoglio alla cassa
Solo a titolo indicativo — il catalogo è espresso in dollari
Nessuna valuta corrisponde.
Scelga la lingua in cui il sito Le parla.
Prima visita?
Ne ha già uno?
Non esiste un ripristino automatico: questo negozio non invia e-mail, quindi non esiste alcun link monouso da richiedere. Lasci l’indirizzo sull’account: verrà gestito manualmente.
Richiesta registrata
Non arriverà nulla nella Sua casella di posta — questo negozio non invia e-mail. Qualcuno se ne occupa manualmente.
L’ha ritrovata?