NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
NShi
A 1000 W desktop switching supply delivering 27 V at 37 A with up to 90 % efficiency, PFC, remote control, adjustable output and full protection from -20 to +60 °C
The NShi RSP-1000-27 delivers a single 27V output rated at 37A for industrial automation, DIY engineering projects and test instrumentation. It provides active PFC, remote on/off switching, remote sensing and an auxiliary output alongside a DC OK signal. Output voltage and constant-current limits are both adjustable to suit custom load requirements. Builders needing multiple rails or standard ATX connectors should look elsewhere.
Conversion efficiency reaches 90 percent, allowing continuous full-load operation from -20 to +60 Celsius. A built-in DC fan handles cooling inside the metal chassis, which doubles as a heatsink for quiet thermal management. Protection circuits guard against short circuit, overload, over-voltage and over-temperature events. The unit is not fanless, so completely silent environments will require a different solution.
Remote sensing compensates for voltage drop across long cables, while the DC OK output simplifies system-level health monitoring. Auxiliary power is available for low-current auxiliary circuits without a separate supply. Voltage and current limits are set via onboard controls rather than software. No mounting brackets, cables or configuration utilities are bundled in the package.
| Chassis Type | Desktop |
|---|
Wire the remote sensing leads directly to the load terminals to compensate for cable drop, and use the auxiliary power output for low-current control circuits; both are screw-terminal connections on the front panel.
The internal DC fan provides cooling up to 60 °C ambient; expect to clean dust from the intake vents periodically and replace the fan if bearing noise appears after extended 1000 W operation.
The unit monitors internal temperature and will shut down if heat exceeds the design limit while delivering 37 A continuously, especially above 60 °C ambient; derate load or improve airflow to avoid trips.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?