NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Přijímáme kryptoměny — takže to, co držíte, můžete utratit za skutečný hardware.Plaťte kryptem, utrácejte ho za skutečný hardware. Pojištěná doprava zdarma po celém světě nad 399 $. Neutrální přepravní krabice bez loga, odesílané z Německa.Pojištěná doprava zdarma nad 399 $. Jakmile se otevře pokladna, je váš kurz zablokovaný na 30 minut.Kurz zablokovaný na 30 minut. Každý výrobek je zapečetěný, jeho sériové číslo je zkontrolované a vztahuje se na něj 24měsíční záruka.Zapečetěno, záruka 24 měsíců.
NShi
A 1000 W desktop switching supply delivering 27 V at 37 A with up to 90 % efficiency, PFC, remote control, adjustable output and full protection from -20 to +60 °C
The NShi RSP-1000-27 delivers a single 27V output rated at 37A for industrial automation, DIY engineering projects and test instrumentation. It provides active PFC, remote on/off switching, remote sensing and an auxiliary output alongside a DC OK signal. Output voltage and constant-current limits are both adjustable to suit custom load requirements. Builders needing multiple rails or standard ATX connectors should look elsewhere.
Conversion efficiency reaches 90 percent, allowing continuous full-load operation from -20 to +60 Celsius. A built-in DC fan handles cooling inside the metal chassis, which doubles as a heatsink for quiet thermal management. Protection circuits guard against short circuit, overload, over-voltage and over-temperature events. The unit is not fanless, so completely silent environments will require a different solution.
Remote sensing compensates for voltage drop across long cables, while the DC OK output simplifies system-level health monitoring. Auxiliary power is available for low-current auxiliary circuits without a separate supply. Voltage and current limits are set via onboard controls rather than software. No mounting brackets, cables or configuration utilities are bundled in the package.
| Chassis Type | Desktop |
|---|
Wire the remote sensing leads directly to the load terminals to compensate for cable drop, and use the auxiliary power output for low-current control circuits; both are screw-terminal connections on the front panel.
The internal DC fan provides cooling up to 60 °C ambient; expect to clean dust from the intake vents periodically and replace the fan if bearing noise appears after extended 1000 W operation.
The unit monitors internal temperature and will shut down if heat exceeds the design limit while delivering 37 A continuously, especially above 60 °C ambient; derate load or improve airflow to avoid trips.
Také v této kategorii
Stejná kategorie, stejná pokladna — osm měn a kurz zamčený na 30 minut.
Měna, ve které platíte, a měna, ve které se zobrazují ceny.
Odesláno z vaší peněženky u pokladny
Pouze pro zobrazení — katalog je veden v dolarech
Žádná měna neodpovídá.
Vyberte jazyk, ve kterém s vámi bude web komunikovat.
Poprvé tady?
Už účet máte?
Neexistuje žádná automatická obnova hesla: tento obchod neposílá žádné e-maily, takže neexistuje jednorázový odkaz, o který by bylo možné požádat. Nechte adresu uvedenou u účtu, vyřídíme ji ručně.
Žádost zaznamenána
Do vaší schránky nic nedorazí — tento obchod neposílá žádné e-maily. Někdo se o to postará ručně.
Vzpomněli jste si?