Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

HP

HP BLc7000 ICE ROHS 1PH 2PS Enclosure 507014-B21

SKU CH-C7SX-WBJHR

A 10U rack enclosure supporting ten fans and six power supplies, shipped with four fans and two redundant 220 V AC units installed

  • TypeRack
  • Supports up to 10 fans for scalable cooling
  • Includes 4 pre-installed fans for immediate airflow
  • Redundant power with 2 of 6 PSU bays populated
  • RoHS and WEEE compliant for environmental standards
  • 10U rack form factor fits standard data-centre cabinets

Blade enclosure for dense compute

The HP BLc7000 ICE ROHS enclosure fits a standard 10U rack and houses up to sixteen server blades in a single chassis. It targets data-centre operators who need high-density processing without spreading workloads across multiple racks. Integrated single-phase power simplifies facility wiring for new deployments. RoHS and WEEE compliance meets common environmental mandates.

Sustained load behaviour

Four fans ship installed and the chassis accepts ten, providing headroom for continuous thermal demand across all blade slots. Dual power supplies operate in redundant mode and the frame supports six units total, so capacity can grow with the workload. This redundancy keeps blades running during a supply failure or hot-swap event. The enclosure itself adds no compute latency; it only delivers power and airflow.

Thermals noise and power

Ten fan bays let operators tune airflow to actual heat output rather than running every slot at maximum speed. Input voltage is 220 V AC, matching typical row-level distribution in many regions. The 17.4-inch square footprint and 32-inch depth leave cable-management space at the rear of a standard cabinet. Green-compliant materials reduce hazardous substance content for regulated environments.

Puncte forte

  • Supports up to 10 fans for scalable cooling
  • Includes 4 pre-installed fans for immediate airflow
  • Redundant power with 2 of 6 PSU bays populated
  • RoHS and WEEE compliant for environmental standards
  • 10U rack form factor fits standard data-centre cabinets

Specificații

TypeRack

Întrebări despre acest articol

How loud and hot does the BLc7000 enclosure get with four fans running continuously?

The chassis supports up to ten fans and ships with four installed; redundant power supplies and single-phase 220 V AC input help manage heat and power draw during all-day operation.

Which power cords and rack hardware must I already have to install this 10U unit?

You need IEC cables for 220 V AC single-phase supply and a 10U rack space measuring at least 17.4 inches wide by 32 inches deep for the rack-mountable enclosure.

Will my existing BladeSystem server blades and interconnects fit straight into this 507014-B21 enclosure?

The BLc7000 ICE chassis accepts standard BladeSystem blades and interconnect modules, so older compatible hardware can be installed without modification.

Tot din acest raion

Clienții au comparat și acestea.

Același raion, aceeași finalizare a comenzii — opt monede și un curs blocat 30 de minute.