Acceptăm criptomonede — astfel, criptomonedele pe care le dețineți pot cumpăra echipamente reale.Plătiți în cripto, cheltuiți-o pe echipamente reale. Livrare asigurată gratuită oriunde în lume peste 399 $. Cartoane neutre, fără marcă, expediate din Germania.Livrare asigurată gratuită peste 399 $. Cursul dumneavoastră este blocat timp de 30 de minute de la deschiderea paginii de plată.Curs blocat 30 de minute. Fiecare articol este sigilat, numărul de serie este verificat, iar produsul este acoperit de o garanție de 24 de luni.Sigilat, garantat 24 de luni.

Produse urmărite Conectare

MINUTEMAN

MINUTEMAN EC2000RTXL2UNC UPS 2000VA 1800W 120V 6x NEMA 5-15/20R

SKU CH-6H8J-M003B MPN EC2000RTXL2UNC

Online UPS delivers 2000VA and 1800W of pure sine-wave power to six NEMA 5-15/20R outlets with extended runtime

  • International Version120V
  • Input Voltage Range0-160VAC
  • Input Frequency50/60Hz, +/-6Hz, Auto-sensing
  • Input ConnectionNEMA 5-20P
  • VA Rating2000VA
  • Watts1800W

Versiunile tăiate există, dar nu sunt disponibile aici.

  • True sine wave output protects sensitive equipment
  • Online double-conversion topology delivers continuous clean power
  • 1800W capacity supports demanding server and network loads
  • Six controllable NEMA 5-15/20R outlets enable managed load shedding
  • Rack or tower form factor fits diverse installation spaces

2000 VA Online UPS for 120 V Racks

The Minuteman Encompass RTXL is a new 2000 VA, 1800 W online double-conversion UPS that accepts 120 V input and provides pure sine-wave output. It mounts in a standard 19-inch rack or stands as a tower and connects through a NEMA 5-20P plug. Six NEMA 5-15/20R outlets supply battery-backed power to servers or network gear. The unit operates from 0 to 40 °C with 10 to 90 percent non-condensing humidity.

Runtime at Half and Full Load

At half load the sealed lead-acid battery delivers 10 minutes of runtime; at full load it provides 3 minutes. The replaceable battery module is BM0070. Output frequency stays within 0.2 Hz of 50 or 60 Hz unless synchronized to the utility. Input voltage range spans 0 to 160 VAC with auto-sensing frequency tolerance of ±6 Hz. Power factor is 0.9.

USB Management and Controllable Outlets

A USB interface enables monitoring and graceful shutdown software integration. All six outlets are individually controllable, allowing scheduled reboots or load shedding. The UPS carries cTUVus, FCC Class A, CE, Energy Star 2.0, DoE 10 CFR Part 430 and RoHS2 approvals. Dimensions are 19.2 x 3.5 x 18.9 inches and weight is 44.1 lbs.

Puncte forte

  • True sine wave output protects sensitive equipment
  • Online double-conversion topology delivers continuous clean power
  • 1800W capacity supports demanding server and network loads
  • Six controllable NEMA 5-15/20R outlets enable managed load shedding
  • Rack or tower form factor fits diverse installation spaces

Specificații

BrandMINUTEMAN
SeriesENCOMPASS RTXL
ModelEC2000RTXL2UNC
International Version120V
Input Voltage Range0-160VAC
Input Frequency50/60Hz, +/-6Hz, Auto-sensing
Input ConnectionNEMA 5-20P
VA Rating2000VA
Watts1800W
Output Voltage120V
Output Frequency50/60Hz, +/-0.2Hz (unless synchronized to utility)
Outlets6
Outlet Type(6) NEMA 5-15/20R
Battery TypeSealed Lead Acid
Battery Run TimeHalf Load: 10 min
Full Load: 3 min
Battery ReplaceableBM0070
ApprovalscTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 /R: 2014), FCC Class A, CE certified, Energy Star 2.0, DoE 10 CFR Part 430, RoHS2 (EU Directive 2011/65/EU)
RackmountableYes
Temperature0° to 40°C (+32° to +104°F)
Humidity10% to 90% non-condensing
Dimensions19.2" x 3.5" x 18.9"
Weight44.1 lbs.
Greutate la expediere20.23 kg
Dimensiunile coletului488 × 480 × 89 mm

Alte versiuni ale acestui model

5 în plus din aceeași gamă

Aceeași familie, memorie, radiator sau frecvență diferite — comparați înainte de a vă decide.

Întrebări despre acest articol

How long will the 1800 W output keep my equipment running during an outage?

At full 1800 W load the internal battery provides about 3 minutes; at roughly half that load it extends to 10 minutes.

What does the NEMA 5-20P input plug require from my circuit?

It needs a 120 V, 20 A branch circuit; the UPS will not connect to a standard 15 A receptacle.

Will the 19.2" x 3.5" x 18.9" chassis fit in my 19-inch rack?

Yes, it is a 2U rack-mountable unit that also supports tower placement on the included feet.

Tot din acest raion

Clienții au comparat și acestea.

Același raion, aceeași finalizare a comenzii — opt monede și un curs blocat 30 de minute.