Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
HP
700W redundant hot-plug power supply for ProLiant DL360 G5 servers with 100-240V input
The HP 399542-B21 is a hot-plug redundant power module rated at 700W. It fits ProLiant DL360 G5 servers across Base, Entry and Performance configurations. IT teams use it to add fault-tolerant power to 1U rack systems without shutting down the host.
The unit accepts 100 to 240 V input and includes active power factor correction. Redundant operation shares load between modules, reducing per-unit stress and fan speed during typical workloads. Hot-swap capability allows replacement while the server remains online.
This supply replaces a failed or missing module in a DL360 G5 chassis to restore N+1 redundancy. The jump is worth it when uptime requirements exceed single-supply risk tolerance. It does not serve platforms outside the listed G5 family.
| Brand | HP |
|---|---|
| Model | 399542-B21 |
| Type | Consumer Electronics |
| Single/Redundant | Redundant |
| Maximum Power | 700W |
| Input Voltage | 100 - 240 V |
| Features | Compatibility: HP ProLiant DL360 G5 HP ProLiant DL360 G5 Base HP ProLiant DL360 G5 Entry HP ProLiant DL360 G5 Performance |
| Teža pošiljke | 2.04 kg |
| Velikost pošiljke | 495 × 203 × 203 mm |
Slide the unit into the hot-plug bay until the latch clicks, then verify the amber LED turns green; the step often missed is confirming both modules show green before closing the chassis.
The internal fan is the only moving part; expect to replace the module when bearing noise appears or the status LED stays amber after reseating.
The 700W maximum output is the hard ceiling; once total draw reaches that level the supply will throttle or shut down to protect the server.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Ni ustreznega jezika.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?