Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
myVolts
DC-DC module isolates a 4.5-5.5V rail to ±5V at 1500VDC with up to 86% efficiency and an operating range of -40°C to +105°C
The myVolts A0505S-1WR2 converts a 4.5-5.5V DC input into a regulated ±5V DC output with 1500VDC isolation. It suits engineers who need a compact SIP or DIP package for embedded systems where input and output grounds must remain separate. The module delivers up to ±100mA per rail with a minimum load of 10mA.
Rated efficiency reaches 86% at full load, with typical figures of 76% to 80% across the operating range. No moving parts are present, so acoustic noise is absent. The unit operates continuously from -40°C to +105°C without derating, making it suitable for industrial environments with wide temperature swings.
Built-in protection guards against over-current, over-voltage and under-voltage conditions during prolonged operation. Maximum capacitive load is rated at 100µF per output, ensuring stable regulation when driving downstream circuitry. The isolation barrier maintains 1500VDC withstand voltage throughout the temperature range.
| Type | AT |
|---|
Mount the SIP or DIP pins into your board power system with a stable 4.5-5.5V DC input; the step often missed is confirming the input voltage stays within ±10% of nominal so the 1500VDC isolation remains effective.
No scheduled maintenance is required; if the module ever fails, replace the entire unit because the internal isolation barrier and protection circuits are not serviceable.
The ±100mA maximum output current is reached first; exceeding it triggers over-current protection and the 76% typical efficiency at full load means noticeable heat rise inside the -40°C to +105°C operating range.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?