Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
OWC
A 32 GB DDR4 ECC VLP UDIMM running at 2666 MHz CL19 for Supermicro MicroBlade 314E-6119M and 314E-6219M servers
This OWC module adds 32 GB of DDR4 2666 memory to Supermicro MicroBlade servers 314E-6119M and 314E-6219M. It is built to JEDEC and RoHS standards for a warranty-safe upgrade. The unbuffered ECC design targets administrators who need error correction in dense blade chassis.
The VLP form factor fits the restricted height of MicroBlade bays without a heat spreader. Operating at 1.2 V, the module draws minimal power and produces little extra heat in the shared airflow path. Silent operation is inherent because the part has no moving components.
The single specification that decides fit is the combination of ECC and unbuffered signalling on a 288-pin DDR4 2666 stick. Buyers whose platforms require registered or load-reduced DIMMs cannot use this module. Systems limited to non-ECC memory will also reject it.
| Brand | OWC |
|---|---|
| Part Number | 2E6V42R832GB |
| Capacity | 32GB |
| Type | 288-Pin DDR4 ECC VLP UDIMM |
| Speed | DDR4 2666 (PC4 21300) |
| CAS Latency | CL19 |
| Voltage | 1.2V |
| ECC | Yes |
| Buffered/Registered | Unbuffered |
| Rank | 2Rx8 |
| Heat Spreader | No |
| Compatible System | Supermicro MicroBlade Server 314E-6119M Supermicro MicroBlade Server 314E-6219M |
Druge različice tega modela
Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.
Power down and unplug the server, open the chassis, align the module notch with the slot key, press firmly until both side latches click, then verify the VLP height clears the blade cover before closing.
No scheduled maintenance is required; keep air pathways clear of dust, and replace the DIMM only if memtest or the server logs report correctable or uncorrectable ECC errors.
The 2666 MT/s JEDEC speed ceiling is reached before thermal throttling, because the unbuffered VLP design has no heat spreader and relies on chassis airflow.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Ni ustreznega jezika.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?