Vertiv GXT5-1500LVRT2UXLTAA UPS 1500VA 1350W 120V 2U Rack Tower
- 120V
- 60-150V
Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
Vertiv
Online double-conversion UPS delivering 3000VA and 2700W with seven configurable 120V outlets in a 2U rack/tower form factor
Option GXT5-3000LVRT2UXLTAA
Prečrtane različice obstajajo, vendar tukaj niso na voljo.
The Vertiv GXT5-3000LVRT2UXLTAA is a new 120V online UPS rated for 3000VA and 2700W. It fits a 2U rack or tower footprint and uses double-conversion topology with a .9 output power factor. Energy Star 2.0 certification confirms efficient operation for critical IT loads.
This unit targets server rooms and network closets wired for NEMA L5-30P supply. Six NEMA 5-20R outlets plus one L5-30R outlet handle mixed plug types. Buyers whose infrastructure runs at other input voltages, or who need more than seven output receptacles, should look at a different unit.
The 2700W figure decides whether connected equipment stays within the UPS capability. Exceeding it risks overload even if the 3000VA apparent-power limit is not reached. Match your total load to this wattage before purchasing.
| Brand | Vertiv |
|---|---|
| Model | GXT5-3000LVRT2UXLTAA |
| International Version | 120V |
| Input Voltage Range | 60-150V |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 110/115/120/125VAC; (user-configurable); +/-3% |
| Outlets | 7 |
| Outlet Type | 1 x NEMA L5-30R, 6 x NEMA 5-20R |
| Dimensions | 3.4" x 16.9" x 21.3" |
| Weight | 66 lbs. |
| Teža pošiljke | 35.02 kg |
| Velikost pošiljke | 716 × 569 × 262 mm |
Druge različice tega modela
Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.
Mount the 2U chassis using the included brackets, connect the NEMA L5-30P input to a 30 A circuit, then attach loads to the single L5-30R and six 5-20R outlets; the step often missed is configuring the output voltage to 110, 115, 120 or 125 VAC before powering on.
Plan to replace the internal battery modules every three to five years; the unit also supports optional temperature, humidity and leak-detection sensors that should be checked during routine inspections.
At 2700 W output the battery runtime becomes the limiting factor before thermal shutdown, since the maximum operating temperature is rated at 104 °F (40 °C).
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Ni ustreznega jezika.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?