Vertiv
Vertiv Liebert GXT5-1000LVRT2UXL UPS 1000VA/1000W 120V 2U
Online double-conversion UPS delivers 1000VA/1000W with zero transfer time, six NEMA 5-15R outlets and 17.9 minutes runtime at half load
- International Version120V
- Input Voltage Range60-150V
- Input Frequency40-70Hz; Auto Sensing
- Input ConnectionNEMA 5-15P
- VA Rating1000VA
- Watts1000W
- Online double-conversion topology delivers zero transfer time
- Unity power factor provides 1000 W from 1000 VA rating
- Six NEMA 5-15R outlets support multiple devices
- 2U rack/tower form factor fits 3.4 in height
- VRLA battery yields 17.9 min at half load
Vertiv GXT5 1000VA Online UPS
The Vertiv Liebert GXT5-1000LVRT2UXL is a double-conversion online UPS rated at 1000VA and 1000W. It accepts 120V input from 60-150V at 40-70Hz and delivers user-configurable output at 110/115/120/125VAC with +/-3% regulation. Six NEMA 5-15R outlets connect via a NEMA 5-15P plug with a 10 ft cord. The 2U rack-tower chassis measures 3.4" x 16.9" x 15.7" and weighs 37 lbs.
Suits mission-critical IT equipment needing zero
IT managers protecting servers, network gear or storage arrays gain continuous power conditioning and battery backup with VRLA cells. Half-load runtime reaches 17.9 minutes while full load provides 6.7 minutes. The unit operates from 32°F to 104°F and stores from -4°F to 140°F in 0-95% non-condensing humidity. UL 1778 4th Edition and CSA 22.2 No 107.3 approvals apply. Buyers needing more than six outlets, alternative receptacle types or longer battery runtime at full load should consider other solutions.
1000W double-conversion capacity decides fit
The single specification that determines suitability is the 1000W output rating combined with online double-conversion topology. If the connected load exceeds 1000W or the application can tolerate standby or line-interactive designs, this unit is not the right match.
Poudarki
- Online double-conversion topology delivers zero transfer time
- Unity power factor provides 1000 W from 1000 VA rating
- Six NEMA 5-15R outlets support multiple devices
- 2U rack/tower form factor fits 3.4 in height
- VRLA battery yields 17.9 min at half load
Specifikacije
| Brand | Vertiv |
|---|---|
| Series | Liebert |
| Model | GXT5-1000LVRT2UXL |
| International Version | 120V |
| Input Voltage Range | 60-150V |
| Input Frequency | 40-70Hz; Auto Sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000VA |
| Watts | 1000W |
| Output Voltage | 110/115/120/125VAC; (user-configurable); +/-3% |
| Outlets | 6 |
| Outlet Type | 6 x NEMA 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Half Load: 17.9 min Full Load: 6.7 min |
| Approvals | UL 1778 4th Edition and CSA 22.2 No 107.3 |
| Temperature | Operating Temperature: 32°F - 104°F (0°-40°) Storage Temperature: -4°F - 140°F (-20°-60°) |
| Humidity | 0% to 95%, non-condensing |
| Dimensions | 3.4" x 16.9" x 15.7" |
| Weight | 37 lbs. |
| Teža pošiljke | 22.63 kg |
| Velikost pošiljke | 617 × 569 × 262 mm |
Vprašanja o tem izdelku
Does the UPS require a NEMA 5-15R wall outlet for its input plug?
Yes, the unit ships with a NEMA 5-15P plug on a 10 ft cord, so a matching NEMA 5-15R receptacle rated for 120 V is required for the input connection.
Will the six NEMA 5-15R outlets power legacy servers that draw up to 1000 W total?
The UPS delivers 1000 W continuous across all six NEMA 5-15R receptacles, supporting legacy loads up to that combined wattage with 0 ns transfer time on battery.
How can I confirm the UPS is regulating voltage within the +/-3 % spec after installation?
Use the colour graphic LCD to view real-time output voltage; it should read between 110 V and 125 V depending on the user-configured setting, indicating regulation is active.
Tudi v tem oddelku
Stranke so primerjale tudi te
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
ModMyMods MOD-0002 3/8" ID x 1/2" OD Clear PVC Tubing DIY Cooling
- Clear