NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Kripto para kabul ediyoruz — böylece elinizdeki koinlerle gerçek donanım alabilirsiniz.Kripto parayla ödeyin, onu gerçek donanıma harcayın. $399 üzeri siparişlerde dünya genelinde sigortalı kargo ücretsizdir. Sade, markasız koliler Almanya’dan gönderilir.$399 üzeri siparişlerde sigortalı kargo ücretsizdir. Ödeme sayfası açıldığında kurunuz 30 dakika kilitli kalır.Kur 30 dakika kilitli. Her ürün mühürlüdür, seri numarası kontrol edilir ve 24 ay garanti kapsamındadır.Mühürlü, 24 ay garantili.
myVolts
Delivers 450 W at 12 V with 37.5 A output, built-in remote sense, forced-air cooling and full protection suite for LED lighting and industrial control systems
The myVolts SE-450 delivers a steady 12 V at 37.5 A for LED lighting, light boxes, strip installations and industrial control cabinets. It is built for integrators who need a single-output unit that fits standard AT mounting and includes a remote-sense function for voltage accuracy at the load.
Forced air cooling comes from a built-in DC ball-bearing fan that runs whenever the unit is powered. Protections against short circuit, overload, over voltage and over temperature activate automatically, keeping the enclosure within safe limits during typical lighting or monitoring duty.
The supply maintains its rated 450 W output continuously thanks to the active cooling design and surge-current limiting at the AC input. Remote sensing compensates for cable drop so the load sees the correct voltage even during extended operation in automation, laser or distribution-cabinet systems.
| Type | AT |
|---|
Mount the unit with clearance for the built-in DC ball bearing fan airflow, connect the AC input after confirming the voltage selector switch position, then wire the 12 V output terminals; the step most often missed is attaching the remote sense leads to the load so voltage drop under 37.5 A is compensated.
The internal DC ball bearing fan is the only moving part; plan to clean dust from its intake vents periodically and replace the fan assembly if bearing noise appears or airflow drops enough to trigger over-temperature protection.
Forced air cooling by the built-in fan sets the practical ceiling; sustained 450 W output at 12 V 37.5 A will hit over-temperature protection first if inlet air exceeds the unit's rated ambient or if dust restricts the fan.
Bu reyondan diğerleri
Aynı raf, aynı sipariş tamamlama — sekiz koin ve 30 dakikalık kur kilidi.
Ödediğiniz koin ve fiyatları gördüğünüz para birimi.
Ödeme sırasında cüzdanınızdan gönderilir.
Yalnızca görüntüleme içindir — katalog USD cinsinden fiyatlandırılır.
Eşleşen para birimi yok.
Sitenin size hangi dilde hitap edeceğini seçin.
İlk kez mi geliyorsunuz?
Zaten hesabınız var mı?
Otomatik bir sıfırlama yoktur: bu mağaza hiç e-posta göndermez, dolayısıyla talep edilecek tek kullanımlık bir bağlantı da yoktur. Adresi hesapta bırakın, elle işleme alınır.
Talep alındı
Gelen kutunuza doğru giden hiçbir şey yok — bu mağaza hiç e-posta göndermez. Bunları biri elle işleme alır.
Hatırladınız mı?