myVolts
myVolts STP6005D DC power supply 0-60V 0-5A factory maintenance
Adjustable 0-60 V, 0-5 A DC supply with dual display, CV/CC auto-switching and short-circuit, over-temperature protection for bench and cabinet use
- TypeAT
- Continuous 0-60V and 0-5A adjustment for flexible bench testing
- Automatic CV/CC crossover keeps output stable when load conditions change
- Dual independent displays show voltage and current at a glance
- Built-in current-limiting, short-circuit and over-temperature protection guards connected gear
- Up to 80% efficiency reduces waste heat during extended maintenance sessions
Adjustable DC output 0-60 V 0-5 A
The myVolts STP6005D is a bench-top DC power supply that delivers continuously adjustable voltage from 0 to 60 V and current from 0 to 5 A. It operates in constant-voltage or constant-current mode with automatic crossover, and the dual display shows both values independently. Efficiency reaches 80 %. It is built for factory maintenance, calibration stations and integration into test cabinets.
Engineers and technicians needing precise
This unit suits engineers and technicians who require a regulated DC source for prototyping, repair or calibration work where fine voltage and current control matter. The 0.5 % + 3 mV line regulation and 50 mVrms ripple support sensitive analogue circuits. Buyers who need higher current, higher voltage, programmable sequencing or remote computer control should look at other equipment.
60 V maximum output voltage
The single specification that decides fit is the 60 V maximum output voltage combined with a 5 A current limit. If the device under test requires more than 60 V or more than 5 A, this supply cannot power it.
Öne çıkanlar
- Continuous 0-60V and 0-5A adjustment for flexible bench testing
- Automatic CV/CC crossover keeps output stable when load conditions change
- Dual independent displays show voltage and current at a glance
- Built-in current-limiting, short-circuit and over-temperature protection guards connected gear
- Up to 80% efficiency reduces waste heat during extended maintenance sessions
Teknik özellikler
| Type | AT |
|---|
Bu ürünle ilgili sorular
At what output current does the load-regulation spec change from 0.1% + 3mV to 0.2% + 5mV?
The load-regulation specification shifts at 3 A; below that it is 0.1% + 3mV, above it becomes 0.2% + 5mV.
What protection features activate during continuous full-load operation to manage heat and faults?
Over-temperature protection, short-circuit protection and current-limiting buck circuitry engage automatically during sustained use.
Which mains fuse must be present in the IEC inlet before the unit will power on?
A 5 A, 250 VAC slow-blow fuse (marked F5AL) is required in the inlet for the supply to operate.