NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Приемаме криптовалута — така монетите, които притежавате, могат да купят истински хардуер.Платете с крипто, похарчете го за истински хардуер. Безплатна застрахована доставка по целия свят над 399 $. Неутрални кашони без марка, изпратени от Германия.Безплатна застрахована доставка над 399 $. Курсът Ви е заключен за 30 минути веднага след отварянето на касата.Курс, заключен за 30 минути. Всеки артикул е запечатан, серийният му номер е проверен, и е покрит с 24-месечна гаранция.Запечатан, 24-месечна гаранция.
HP
A UPS management module that provides three-phase DirectFlow power distribution at 30A and 400V-415V with IEC309 input and output connections
The HP AF478A is a DirectFlow UPS management module rated for 30 A at 400 V to 415 V three-phase input. It integrates charger, inverter and active filter functions into a single compact unit for HP servers and storage. The module uses IEC 309 connectors for both input and output. It is designed to work with part numbers AF478A and G9Y75A.
DirectFlow technology removes the active front-end AC/DC conversion steps, delivering efficiency exceeding 99 %. Integrated active current correction keeps the power factor close to unity even at low loads. The design reduces both physical size and cost compared with traditional UPS architectures. Clean power output helps lower overall energy costs.
This module replaces a conventional UPS power management unit in an existing DirectFlow rack system. It is suited for installations that need a high-density 12 kW backup solution without the footprint of legacy equipment. Buyers who require a different current rating or single-phase operation should look elsewhere. The jump is worthwhile when expanding capacity within the same DirectFlow chassis.
| Brand | HP |
|---|---|
| Model | AF478A |
| Type | UPS management module |
| Features | Three Phase,DirectFlow |
Mount the module in the DirectFlow UPS frame, connect the IEC 309 three-phase input and output cables at 400 V to 415 V, then secure the 30 A circuit-breaker linkage; the step often missed is torquing the IEC 309 terminals to the specified value before energising.
Plan to replace the internal battery packs that supply the DirectFlow UPS when runtime drops below requirements; the management module itself has no user-serviceable parts, so only the battery trays need periodic swap-out.
The 30 A three-phase input rating at 400 V to 415 V is the first hard limit; exceeding it trips the IEC 309 breaker, so sustained draw must stay within the 30 A per phase envelope.
Още от този рафт
Същият рафт, същата каса — осем монети и заключване на курса за 30 минути.
Това, което изпращате, и това, в което четете цените.
Изпратено от Вашия портфейл при поръчката
Само за визуализация — каталогът е в долари
Никоя валута не съответства.
Изберете езика, на който сайтът да Ви говори.
Нови сте тук?
Вече имате профил?
Няма автоматично нулиране: този магазин не изпраща имейли, така че няма еднократна връзка, която да поискате. Оставете адреса в профила си и той ще бъде обработен ръчно.
Заявката е приета
Нищо няма да пристигне във Вашата пощенска кутия — този магазин изобщо не изпраща имейли. Заявките се обработват ръчно.
Спомнихте си я?