Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.
HP
A UPS management module that provides three-phase DirectFlow power distribution at 30A and 400V-415V with IEC309 input and output connections
The HP AF478A is a DirectFlow UPS management module rated for 30 A at 400 V to 415 V three-phase input. It integrates charger, inverter and active filter functions into a single compact unit for HP servers and storage. The module uses IEC 309 connectors for both input and output. It is designed to work with part numbers AF478A and G9Y75A.
DirectFlow technology removes the active front-end AC/DC conversion steps, delivering efficiency exceeding 99 %. Integrated active current correction keeps the power factor close to unity even at low loads. The design reduces both physical size and cost compared with traditional UPS architectures. Clean power output helps lower overall energy costs.
This module replaces a conventional UPS power management unit in an existing DirectFlow rack system. It is suited for installations that need a high-density 12 kW backup solution without the footprint of legacy equipment. Buyers who require a different current rating or single-phase operation should look elsewhere. The jump is worthwhile when expanding capacity within the same DirectFlow chassis.
| Brand | HP |
|---|---|
| Model | AF478A |
| Type | UPS management module |
| Features | Three Phase,DirectFlow |
Mount the module in the DirectFlow UPS frame, connect the IEC 309 three-phase input and output cables at 400 V to 415 V, then secure the 30 A circuit-breaker linkage; the step often missed is torquing the IEC 309 terminals to the specified value before energising.
Plan to replace the internal battery packs that supply the DirectFlow UPS when runtime drops below requirements; the management module itself has no user-serviceable parts, so only the battery trays need periodic swap-out.
The 30 A three-phase input rating at 400 V to 415 V is the first hard limit; exceeding it trips the IEC 309 breaker, so sustained draw must stay within the 30 A per phase envelope.
Ook in deze afdeling
Dezelfde afdeling, dezelfde kassa — acht munten en een koers die 30 minuten vaststaat.
Waarmee u betaalt, en waarin u de prijzen leest.
Verzonden vanuit uw wallet bij het afrekenen
Alleen ter weergave — de catalogus is geprijsd in USD
Geen valuta gevonden.
Kies de taal waarin de site met u spreekt.
Nieuw hier?
Al een account?
Er is geen automatisch herstel: deze winkel verstuurt geen e-mail, dus er is geen eenmalige link om aan te vragen. Laat het adres op het account achter en het wordt handmatig opgepakt.
Verzoek genoteerd
Er is niets onderweg naar uw inbox — deze winkel verstuurt helemaal geen e-mail. Iemand pakt dit handmatig op.
Weet u het weer?