Micron Technology, Inc. MT4JTF12864AZ-1G4D1 1GB DDR3 1333 Desktop RAM
- 1GB
- DDR3 1333 (PC3 1060…
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
HP
A UPS management module that provides three-phase DirectFlow power distribution at 30A and 400V-415V with IEC309 input and output connections
The HP AF478A is a DirectFlow UPS management module rated for 30 A at 400 V to 415 V three-phase input. It integrates charger, inverter and active filter functions into a single compact unit for HP servers and storage. The module uses IEC 309 connectors for both input and output. It is designed to work with part numbers AF478A and G9Y75A.
DirectFlow technology removes the active front-end AC/DC conversion steps, delivering efficiency exceeding 99 %. Integrated active current correction keeps the power factor close to unity even at low loads. The design reduces both physical size and cost compared with traditional UPS architectures. Clean power output helps lower overall energy costs.
This module replaces a conventional UPS power management unit in an existing DirectFlow rack system. It is suited for installations that need a high-density 12 kW backup solution without the footprint of legacy equipment. Buyers who require a different current rating or single-phase operation should look elsewhere. The jump is worthwhile when expanding capacity within the same DirectFlow chassis.
| Brand | HP |
|---|---|
| Model | AF478A |
| Type | UPS management module |
| Features | Three Phase,DirectFlow |
Mount the module in the DirectFlow UPS frame, connect the IEC 309 three-phase input and output cables at 400 V to 415 V, then secure the 30 A circuit-breaker linkage; the step often missed is torquing the IEC 309 terminals to the specified value before energising.
Plan to replace the internal battery packs that supply the DirectFlow UPS when runtime drops below requirements; the management module itself has no user-serviceable parts, so only the battery trays need periodic swap-out.
The 30 A three-phase input rating at 400 V to 415 V is the first hard limit; exceeding it trips the IEC 309 breaker, so sustained draw must stay within the 30 A per phase envelope.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?