NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
APC
A 2U rackmount UPS delivers 1920 VA pure sine-wave output with automatic voltage regulation, eight NEMA outlets, cloud monitoring via SmartConnect, and a bundled 16 GB USB 3.0 drive
The APC Smart-UPS SMT2200RM2UC delivers 1920 VA and 1920 W of line-interactive pure sine wave power in a 2U rackmount chassis. It protects servers, storage arrays, VoIP gear and point-of-sale systems from outages and voltage fluctuations. Automatic Voltage Regulation corrects brownouts and overvoltages without draining the battery. A bundled 16 GB USB 3.0 drive is included for documentation or firmware files.
The unit operates as a line-interactive UPS with Automatic Voltage Regulation, so the inverter runs only during utility failures or severe deviations, keeping audible noise low in normal conditions. Input connects via a NEMA 5-20P plug drawing up to 20 A, while the eight output receptacles — six NEMA 5-15R and two NEMA 5-20R — distribute conditioned power to attached loads. The 2U form factor fits standard 19-inch racks with a depth of 26.89 in.
The single specification that decides fit is the 1920 VA / 1920 W pure sine wave rating, which must equal or exceed the combined load of every device you intend to protect. Buyers whose equipment demands higher apparent or real power, or who require extended runtime beyond the internal battery, should size a larger unit or add external battery packs. The SmartSlot and SmartConnect Ethernet port enable optional network management and cloud monitoring for environments that need remote visibility.
Der er endnu ikke offentliggjort specifikationer for denne vare.
Mount the 2U unit using the included brackets, plug the NEMA 5-20P input into a 20 A branch circuit, then connect the battery cable inside the front bezel before powering on — skipping the battery connection is the common oversight.
The internal lead-acid battery cartridge typically lasts three to five years; replace it when the LCD shows a battery warning or self-test failure, using the hot-swap tray without shutting down connected loads.
At 1920 W the battery runtime is approximately 15 minutes, so the energy capacity of the internal pack is the first constraint under sustained maximum draw.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?