Thermalright MC-2 ARGB Memory Cooler White 3200 RPM
- Fan & Heatsinks
- DDR/DDR2/DDR3/DDR4/…
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
Dynatron
Passive copper heatsink for 1U servers, supporting LGA1700 sockets and 125W TDP
The Dynatron Q1 is a passive copper heatsink designed for Intel LGA1700 processors in 1U server chassis. It targets system builders who need silent, zero-maintenance cooling within a single rack-unit height. This cooler suits environments where airflow is managed by the chassis rather than a dedicated fan. It is not for builders who need active cooling for higher thermal loads or overclocking headroom.
The heatsink dissipates up to 125 watts of CPU heat without a fan, relying entirely on forced airflow from the server chassis. Copper construction transfers heat efficiently from the processor die to the fin stack. Acoustic output is effectively zero because no moving parts are present. Power draw is nil, as the unit requires no electrical connection.
Under continuous load the cooler maintains thermal equilibrium as long as chassis airflow meets the 125 watt dissipation requirement. Passive operation means performance scales directly with the volume and velocity of air supplied by the system fans. Thermal throttling may occur if chassis airflow is restricted or if the processor exceeds the rated thermal design power.
Der er endnu ikke offentliggjort specifikationer for denne vare.
Align the mounting brackets with the LGA1700 socket holes, apply thermal paste to the CPU, place the copper heatsink, and secure it with the supplied screws. The step often missed is tightening the screws in a diagonal sequence to ensure even pressure.
As a passive design with no moving parts, the Q1 requires no fan replacement. Periodically remove dust from the copper fins using compressed air to maintain the 125 W heat dissipation capacity.
The 125 W TDP rating is the ceiling; sustained loads at this level will raise the heatsink temperature until the CPU hits its internal throttle point, as there is no active airflow to increase dissipation.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?