Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

MINUTEMAN

MINUTEMAN ED8KRT-6KTF2 UPS 8000VA 6930W 208-240V 120V Rack/Tower

SKU CH-YEHD-2HZ0Q MPN ED8KRT-6KTF2

Online double-conversion UPS delivering 8,000VA/6,930W with 120V and 208-240V outputs, hot-swappable batteries, and 3,140-joule surge protection

  • International Version208 (Default), 220, 230, 240VAC
  • Input Voltage Range180-280VAC
  • Input Frequency40 to 70Hz at Full Load
  • Input ConnectionHardwire only
  • VA Rating8,000VA
  • Watts6930W

De overstregede versioner findes, men er ikke på lager her.

  • Online double-conversion topology protects critical loads with clean sine-wave output
  • 6930 W continuous capacity supports dense server racks and network gear
  • 11 minutes runtime at half load gives time for graceful shutdown
  • Hot-swappable BM0098 battery modules enable replacement without power interruption
  • Touchscreen LCD panel provides real-time status and configuration at a glance

Enterprise Online UPS

The Minuteman Endeavor ED8KRT-6KTF2 is a double-conversion UPS rated at 8000VA and 6930W for 208-240V environments. It accepts hardwire input at 180-280VAC and 40-70Hz, delivering regulated output at 50/60Hz with +/-0.1Hz precision. The unit provides five 208-240V outlet groups and sixteen 120V receptacles for mixed-voltage loads.

Sustained Load Behavior

At full 6930W load the internal batteries supply power for three minutes; at half load the runtime extends to eleven minutes. Independent battery chargers support hot-swappable BM0098 modules for continuous operation during replacement. Surge protection is rated at 3140 joules across the operating range of 0-40°C.

Installation and Common Issues

The 5U rack/tower chassis measures 15.36 x 17.24 x 28.74 inches and weighs 347.13 lbs, requiring mechanical handling equipment and hardwire electrical installation. A front-panel touchscreen LCD simplifies configuration, while a DB-9 port provides basic monitoring. Buyers needing network management cards or extended runtime beyond the internal battery capacity must source those accessories separately.

Fordele

  • Online double-conversion topology protects critical loads with clean sine-wave output
  • 6930 W continuous capacity supports dense server racks and network gear
  • 11 minutes runtime at half load gives time for graceful shutdown
  • Hot-swappable BM0098 battery modules enable replacement without power interruption
  • Touchscreen LCD panel provides real-time status and configuration at a glance

Specifikationer

BrandMINUTEMAN
SeriesENDEAVOR
ModelED8KRT-6KTF2
International Version208 (Default), 220, 230, 240VAC
Input Voltage Range180-280VAC
Input Frequency40 to 70Hz at Full Load
Input ConnectionHardwire only
VA Rating8,000VA
Watts6930W
Output Voltage208 (Default), 220, 230, 240VAC
Output Frequency50/60Hz, +/-0.1Hz
Outlets5
Outlet Type(2) L6-30R / (2) L6-20R / (1) 3-wire Terminal Block (208-240VAC)
(16) 5-15/20R (120VAC)
Battery Run TimeHalf Load: 11 min
Full Load: 3 min
Battery ReplaceableBM0098
Interface PortDB-9
ApprovalscUL, CE, UL1778, FCC Class B, Energy Star 2.0, RoHS2
Surge Energy Rating3140 Joules
TemperatureOperating Temperature: +32° to +104°F (0° to +40°C)
Storage Temperature: +5° to +131°F (-15° to +55°C)
Humidity0 to 95%, non-condensing
Dimensions15.36" x 17.24" x 28.74"
Weight347.13 lbs.
Forsendelsesvægt157.44 kg
Pakkestørrelse729 × 437 × 391 mm

Andre versioner af denne model

5 flere i samme serie

Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.

Spørgsmål om denne vare

How much heat does the 6930W UPS produce when running at full load all day?

The unit operates between 32°F and 104°F, so sustained full-load use stays within that range without extra cooling requirements.

What electrical supply must already be in place for the hardwire-only input?

A 180-280VAC single-phase feed at 40-70Hz, terminated in a junction box, is required before installation.

Will the DB-9 port and 5-15/20R outlets work with my older 120V servers and monitoring software?

Yes, the sixteen 5-15/20R outlets deliver 120VAC and the DB-9 interface supports standard UPS management protocols.