Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.

Spremljani izdelki Prijava

MINUTEMAN

MINUTEMAN ED8KRT-6KTF2 UPS 8000VA 6930W 208-240V 120V Rack/Tower

SKU CH-YEHD-2HZ0Q MPN ED8KRT-6KTF2

Online double-conversion UPS delivering 8,000VA/6,930W with 120V and 208-240V outputs, hot-swappable batteries, and 3,140-joule surge protection

  • International Version208 (Default), 220, 230, 240VAC
  • Input Voltage Range180-280VAC
  • Input Frequency40 to 70Hz at Full Load
  • Input ConnectionHardwire only
  • VA Rating8,000VA
  • Watts6930W

Prečrtane različice obstajajo, vendar tukaj niso na voljo.

  • Online double-conversion topology protects critical loads with clean sine-wave output
  • 6930 W continuous capacity supports dense server racks and network gear
  • 11 minutes runtime at half load gives time for graceful shutdown
  • Hot-swappable BM0098 battery modules enable replacement without power interruption
  • Touchscreen LCD panel provides real-time status and configuration at a glance

Enterprise Online UPS

The Minuteman Endeavor ED8KRT-6KTF2 is a double-conversion UPS rated at 8000VA and 6930W for 208-240V environments. It accepts hardwire input at 180-280VAC and 40-70Hz, delivering regulated output at 50/60Hz with +/-0.1Hz precision. The unit provides five 208-240V outlet groups and sixteen 120V receptacles for mixed-voltage loads.

Sustained Load Behavior

At full 6930W load the internal batteries supply power for three minutes; at half load the runtime extends to eleven minutes. Independent battery chargers support hot-swappable BM0098 modules for continuous operation during replacement. Surge protection is rated at 3140 joules across the operating range of 0-40°C.

Installation and Common Issues

The 5U rack/tower chassis measures 15.36 x 17.24 x 28.74 inches and weighs 347.13 lbs, requiring mechanical handling equipment and hardwire electrical installation. A front-panel touchscreen LCD simplifies configuration, while a DB-9 port provides basic monitoring. Buyers needing network management cards or extended runtime beyond the internal battery capacity must source those accessories separately.

Poudarki

  • Online double-conversion topology protects critical loads with clean sine-wave output
  • 6930 W continuous capacity supports dense server racks and network gear
  • 11 minutes runtime at half load gives time for graceful shutdown
  • Hot-swappable BM0098 battery modules enable replacement without power interruption
  • Touchscreen LCD panel provides real-time status and configuration at a glance

Specifikacije

BrandMINUTEMAN
SeriesENDEAVOR
ModelED8KRT-6KTF2
International Version208 (Default), 220, 230, 240VAC
Input Voltage Range180-280VAC
Input Frequency40 to 70Hz at Full Load
Input ConnectionHardwire only
VA Rating8,000VA
Watts6930W
Output Voltage208 (Default), 220, 230, 240VAC
Output Frequency50/60Hz, +/-0.1Hz
Outlets5
Outlet Type(2) L6-30R / (2) L6-20R / (1) 3-wire Terminal Block (208-240VAC)
(16) 5-15/20R (120VAC)
Battery Run TimeHalf Load: 11 min
Full Load: 3 min
Battery ReplaceableBM0098
Interface PortDB-9
ApprovalscUL, CE, UL1778, FCC Class B, Energy Star 2.0, RoHS2
Surge Energy Rating3140 Joules
TemperatureOperating Temperature: +32° to +104°F (0° to +40°C)
Storage Temperature: +5° to +131°F (-15° to +55°C)
Humidity0 to 95%, non-condensing
Dimensions15.36" x 17.24" x 28.74"
Weight347.13 lbs.
Teža pošiljke157.44 kg
Velikost pošiljke729 × 437 × 391 mm

Druge različice tega modela

še 5 v isti paleti

Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.

Vprašanja o tem izdelku

How much heat does the 6930W UPS produce when running at full load all day?

The unit operates between 32°F and 104°F, so sustained full-load use stays within that range without extra cooling requirements.

What electrical supply must already be in place for the hardwire-only input?

A 180-280VAC single-phase feed at 40-70Hz, terminated in a junction box, is required before installation.

Will the DB-9 port and 5-15/20R outlets work with my older 120V servers and monitoring software?

Yes, the sixteen 5-15/20R outlets deliver 120VAC and the DB-9 interface supports standard UPS management protocols.

Tudi v tem oddelku

Stranke so primerjale tudi te

Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.