MINUTEMAN ED8KRT 8000VA 7200W UPS
8 kVA / 7200 W rack-tower UPS with true sine-wave output, configurable 208-240 V, hot-swappable batteries and 3 min runtime at full load
- International Version208 (Default), 220, 230, 240VAC
- Input Voltage Range180-280VAC
- Input Frequency40 to 70Hz at Full Load
- Input ConnectionHardwire only
- VA Rating8,000VA
- Watts7200W
Model ED8KRT
- ED8KRT
- ED1000RTXL2U
- ED1000RTXL2UNC
- ED10KRT
- ED10KRT-10KTF2
- ED10KRT-3KTF
- ED10KRT-5KTF
- ED10KRT-6KTF2
- ED10KRT-8KTF2
- ED10KTF
- ED2000RTXL2U
- ED2000RTXL2UNC
Prikaži še 16 konfiguracij
- ED3000RTXL2U
- ED3000RTXL2UNC
- ED-3KTF
- ED5KRT
- ED5KRT-3KTF
- ED5KRT-5KTF
- ED-5KTF
- ED6KRT
- ED6KRT-3KTF
- ED6KRT-5KTF
- ED6KRT-6KTF2
- ED6KTF
- ED8KRT-3KTF
- ED8KRT-5KTF
- ED8KRT-6KTF2
- ED8KRT-8KTF2
Prečrtane različice obstajajo, vendar tukaj niso na voljo.
- 8,000VA capacity protects critical rack equipment
- True sine-wave output delivers clean power to sensitive loads
- Hot-swappable BM0098 batteries enable replacement without downtime
- Touchscreen LCD panel simplifies configuration and monitoring
- 3,140-joule surge rating shields connected hardware from spikes
8000VA Rack/Tower UPS for Critical Loads
The Minuteman Endeavor ED8KRT is an 8000VA, 7200W true sine-wave UPS built for 208V, 220V, 230V or 240V single-phase environments. It supplies five outlets — four L6-30R, two L6-20R and a three-wire terminal block — making it suitable for server rooms and network closets that need hardwired input and extended runtime options.
Hardwired Install with Hot-Swap Batteries
Input connection is hardwire only, so a qualified electrician must terminate the feed. The unit occupies 5U in a rack and weighs 170.81 lbs, requiring adequate support rails or a stable floor surface. Batteries are front-accessible, tool-less and hot-swappable using the BM0098 pack, allowing replacement without powering down connected equipment.
Check Voltage, Phase and Breaker Capacity
Verify that your supply sits within the 180-280VAC window and that the service is single-phase 50/60Hz. Confirm the distribution panel can deliver the required current for an 8000VA load and that the L6-30R or L6-20R plugs match your gear. The DB-9 port provides basic monitoring; network cards are not included.
Poudarki
- 8,000VA capacity protects critical rack equipment
- True sine-wave output delivers clean power to sensitive loads
- Hot-swappable BM0098 batteries enable replacement without downtime
- Touchscreen LCD panel simplifies configuration and monitoring
- 3,140-joule surge rating shields connected hardware from spikes
Specifikacije
| Brand | MINUTEMAN |
|---|---|
| Series | ENDEAVOR |
| Model | ED8KRTED6KRT |
| International Version | 208 (Default), 220, 230, 240VAC |
| Input Voltage Range | 180-280VAC |
| Input Frequency | 40 to 70Hz at Full Load |
| Input Connection | Hardwire only |
| VA Rating | 8,000VA |
| Watts | 7200W |
| Output Voltage | 208 (Default), 220, 230, 240VAC |
| Output Frequency | 50/60Hz, +/-0.1Hz |
| Outlets | 5 |
| Outlet Type | (4) L6-30R / (2) L6-20R / (1) 3-wire Terminal Block |
| Battery Run Time | Half Load: 11 min Full Load: 3 min |
| Battery Replaceable | BM0098 |
| Interface Port | DB-9 |
| Approvals | cUL, CE, UL1778, FCC Class B, Energy Star 2.0, RoHS2 |
| Surge Energy Rating | 3140 Joules |
| Temperature | Operating Temperature: +32° to +104°F (0° to +40°C) Storage Temperature: +5° to +131°F (-15° to +55°C) |
| Humidity | 0 to 95%, non-condensing |
| Dimensions | 8.54" x 17.24" x 28.74" |
| Weight | 170.81 lbs. |
| Teža pošiljke | 77.47 kg |
| Velikost pošiljke | 729 × 437 × 216 mm |
Druge različice tega modela
še 5 v isti paleti
Ista družina, različen pomnilnik, hladilnik ali takt — primerjajte, preden se odločite.
MINUTEMAN ED5KRT UPS 5000VA 4500W 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED6KRT UPS 6000VA 5400W 208-240V 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED5KRT-5KTF UPS 5000VA 4275W 208-240V Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED6KRT-3KTF 6000VA 5265W UPS
- 208 (Default), 220,…
- 156-280VAC
Vprašanja o tem izdelku
How can I confirm the UPS is delivering true sine-wave output at 208 VAC after installation?
The multi-colour touchscreen LCD panel displays real-time output voltage and frequency; verify it reads 208 VAC and 50/60 Hz ±0.1 Hz while the load is connected.
What ships with the ED8KRT and which items must be sourced separately?
The unit includes the 4U rack/tower chassis, internal BM0098 battery modules, DB-9 interface port and terminal-block hardware; input power cables, L6-30R/L6-20R output cords and any external battery cabinets are not included.
Which output voltage version should I select for a 230 VAC server rack?
Choose the 230 VAC international version; the UPS defaults to 208 VAC but can be configured to 220, 230 or 240 VAC via the touchscreen to match your rack’s distribution.
Tudi v tem oddelku
Stranke so primerjale tudi te
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case