MINUTEMAN ED8KRT 8000VA 7200W UPS
8 kVA / 7200 W rack-tower UPS with true sine-wave output, configurable 208-240 V, hot-swappable batteries and 3 min runtime at full load
- International Version208 (Default), 220, 230, 240VAC
- Input Voltage Range180-280VAC
- Input Frequency40 to 70Hz at Full Load
- Input ConnectionHardwire only
- VA Rating8,000VA
- Watts7200W
Model ED8KRT
- ED8KRT
- ED1000RTXL2U
- ED1000RTXL2UNC
- ED10KRT
- ED10KRT-10KTF2
- ED10KRT-3KTF
- ED10KRT-5KTF
- ED10KRT-6KTF2
- ED10KRT-8KTF2
- ED10KTF
- ED2000RTXL2U
- ED2000RTXL2UNC
Show 16 more configurations
- ED3000RTXL2U
- ED3000RTXL2UNC
- ED-3KTF
- ED5KRT
- ED5KRT-3KTF
- ED5KRT-5KTF
- ED-5KTF
- ED6KRT
- ED6KRT-3KTF
- ED6KRT-5KTF
- ED6KRT-6KTF2
- ED6KTF
- ED8KRT-3KTF
- ED8KRT-5KTF
- ED8KRT-6KTF2
- ED8KRT-8KTF2
Struck-through versions exist but are not stocked here.
- 8,000VA capacity protects critical rack equipment
- True sine-wave output delivers clean power to sensitive loads
- Hot-swappable BM0098 batteries enable replacement without downtime
- Touchscreen LCD panel simplifies configuration and monitoring
- 3,140-joule surge rating shields connected hardware from spikes
8000VA Rack/Tower UPS for Critical Loads
The Minuteman Endeavor ED8KRT is an 8000VA, 7200W true sine-wave UPS built for 208V, 220V, 230V or 240V single-phase environments. It supplies five outlets — four L6-30R, two L6-20R and a three-wire terminal block — making it suitable for server rooms and network closets that need hardwired input and extended runtime options.
Hardwired Install with Hot-Swap Batteries
Input connection is hardwire only, so a qualified electrician must terminate the feed. The unit occupies 5U in a rack and weighs 170.81 lbs, requiring adequate support rails or a stable floor surface. Batteries are front-accessible, tool-less and hot-swappable using the BM0098 pack, allowing replacement without powering down connected equipment.
Check Voltage, Phase and Breaker Capacity
Verify that your supply sits within the 180-280VAC window and that the service is single-phase 50/60Hz. Confirm the distribution panel can deliver the required current for an 8000VA load and that the L6-30R or L6-20R plugs match your gear. The DB-9 port provides basic monitoring; network cards are not included.
Highlights
- 8,000VA capacity protects critical rack equipment
- True sine-wave output delivers clean power to sensitive loads
- Hot-swappable BM0098 batteries enable replacement without downtime
- Touchscreen LCD panel simplifies configuration and monitoring
- 3,140-joule surge rating shields connected hardware from spikes
Specifications
| Brand | MINUTEMAN |
|---|---|
| Series | ENDEAVOR |
| Model | ED8KRTED6KRT |
| International Version | 208 (Default), 220, 230, 240VAC |
| Input Voltage Range | 180-280VAC |
| Input Frequency | 40 to 70Hz at Full Load |
| Input Connection | Hardwire only |
| VA Rating | 8,000VA |
| Watts | 7200W |
| Output Voltage | 208 (Default), 220, 230, 240VAC |
| Output Frequency | 50/60Hz, +/-0.1Hz |
| Outlets | 5 |
| Outlet Type | (4) L6-30R / (2) L6-20R / (1) 3-wire Terminal Block |
| Battery Run Time | Half Load: 11 min Full Load: 3 min |
| Battery Replaceable | BM0098 |
| Interface Port | DB-9 |
| Approvals | cUL, CE, UL1778, FCC Class B, Energy Star 2.0, RoHS2 |
| Surge Energy Rating | 3140 Joules |
| Temperature | Operating Temperature: +32° to +104°F (0° to +40°C) Storage Temperature: +5° to +131°F (-15° to +55°C) |
| Humidity | 0 to 95%, non-condensing |
| Dimensions | 8.54" x 17.24" x 28.74" |
| Weight | 170.81 lbs. |
| Shipping weight | 77.47 kg |
| Package size | 729 × 437 × 216 mm |
Other versions of this model
5 more in the same range
Same family, different memory, cooler or clock — compare before you commit.
MINUTEMAN ED5KRT UPS 5000VA 4500W 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED6KRT UPS 6000VA 5400W 208-240V 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED5KRT-5KTF UPS 5000VA 4275W 208-240V Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED6KRT-3KTF 6000VA 5265W UPS
- 208 (Default), 220,…
- 156-280VAC
Questions about this item
How can I confirm the UPS is delivering true sine-wave output at 208 VAC after installation?
The multi-colour touchscreen LCD panel displays real-time output voltage and frequency; verify it reads 208 VAC and 50/60 Hz ±0.1 Hz while the load is connected.
What ships with the ED8KRT and which items must be sourced separately?
The unit includes the 4U rack/tower chassis, internal BM0098 battery modules, DB-9 interface port and terminal-block hardware; input power cables, L6-30R/L6-20R output cords and any external battery cabinets are not included.
Which output voltage version should I select for a 230 VAC server rack?
Choose the 230 VAC international version; the UPS defaults to 208 VAC but can be configured to 220, 230 or 240 VAC via the touchscreen to match your rack’s distribution.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case