MINUTEMAN
MINUTEMAN ED1000RTXL2U 1000VA 900W 2U UPS
1000 VA on-line UPS with eight NEMA 5-15R outlets, 2U rack-mountable design and 0.9 power factor
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz +/- 6Hz Auto-sensing
- Input ConnectionNEMA 5-15P
- VA Rating1000VA
- Watts900W
Model ED1000RTXL2U
- ED1000RTXL2U
- ED1000RTXL2UNC
- ED10KRT
- ED10KRT-10KTF2
- ED10KRT-3KTF
- ED10KRT-5KTF
- ED10KRT-6KTF2
- ED10KRT-8KTF2
- ED10KTF
- ED2000RTXL2U
- ED2000RTXL2UNC
- ED3000RTXL2U
Show 16 more configurations
- ED3000RTXL2UNC
- ED-3KTF
- ED5KRT
- ED5KRT-3KTF
- ED5KRT-5KTF
- ED-5KTF
- ED6KRT
- ED6KRT-3KTF
- ED6KRT-5KTF
- ED6KRT-6KTF2
- ED6KTF
- ED8KRT
- ED8KRT-3KTF
- ED8KRT-5KTF
- ED8KRT-6KTF2
- ED8KRT-8KTF2
Struck-through versions exist but are not stocked here.
- True on-line double-conversion technology protects equipment from all power disturbances
- Compact 2U rackmount form factor fits high-density server cabinets and racks
- Flexible tower, rack or wall mounting adapts to any installation environment
- 9 output power factor delivers 900 W real power from 1000 VA rating
- LCD display and three controllable load banks simplify monitoring and management
Compact double-conversion UPS
The MINUTEMAN ED1000RTXL2U is a 1000VA 900W on-line double-conversion UPS in a 2U rackmount chassis. It accepts 120V input across a 0-160VAC range and delivers 120V or user-selectable 110V output with a .9 power factor. Eight NEMA 5-15R receptacles support tower, rack or optional wall mounting for dense IT environments.
Three load banks and replaceable battery
Three independently controllable load banks let administrators shed non-critical outlets during extended outages. The sealed lead-acid battery module BM0035 is user-replaceable and recharges to 90 percent in 8 hours. Economy mode reduces operating losses when utility power is stable.
Rack ears attached and LCD status
Rackmount ears ship pre-attached for immediate 19-inch cabinet installation. An LCD panel reports voltage, load and battery status at a glance. The unit operates from 32 to 104°F in up to 95 percent non-condensing humidity and carries cTUVus, FCC, CE, Energy Star and RoHS2 approvals.
Highlights
- True on-line double-conversion technology protects equipment from all power disturbances
- Compact 2U rackmount form factor fits high-density server cabinets and racks
- Flexible tower, rack or wall mounting adapts to any installation environment
- 9 output power factor delivers 900 W real power from 1000 VA rating
- LCD display and three controllable load banks simplify monitoring and management
Specifications
| Brand | MINUTEMAN |
|---|---|
| Model | ED1000RTXL2U |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/- 6Hz Auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000VA |
| Watts | 900W |
| Output Voltage | 120VAC, User selectable: 110VAC |
| Output Frequency | 50/60Hz +/- 0.5Hz unless synchronized to line |
| Outlets | 8 |
| Outlet Type | (8) NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 11 min Full Load: 3 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0035 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU) |
| Surge Energy Rating | 1000 Joules |
| Temperature | Operating Temperature: +32 to +104°F (0 to 40°C) Storage Temperature: +5 to +113°F (-15 to +45°C) |
| Humidity | 95% non-condensing |
| Dimensions | 13.3" x 3.5" x 19" |
| Weight | 29.3 lbs. |
| Shipping weight | 16.81 kg |
| Package size | 599 × 508 × 224 mm |
Questions about this item
When will the internal battery pack need replacement and which part number should I order?
The sealed lead‑acid cells are user‑replaceable; order part BM0035 when runtime drops below the rated 11 minutes at half load or 3 minutes at full load.
What is the first limit reached during continuous full‑load operation?
At 900 W the battery depletes after 3 minutes, so runtime is the limiting factor before thermal or overload protection engages.
How much audible noise and heat does the unit produce when running all day in a 2U rack?
The on‑line double‑conversion design runs its inverter continuously; expect typical rack‑mount fan noise and exhaust heat within the 0‑40 °C operating range.
Also in this aisle