APC
APC AP7894 Metered Zero U Rack 5.7kVA PDU 208V 10ft
A metered zero-U rack PDU delivering 5.7 kVA at 208 V AC with a 10 ft cord
- TypeMetered
- Rack SizeZero U Rack
- Input Voltage208 V AC
- Cord Length10 ft
- Output Voltage208 V AC
- Output Frequency50/60Hz
- Metered monitoring tracks power usage in real time
- Zero U vertical mounting saves horizontal rack space
- 7 kVA capacity supports high-density equipment loads
- 208 V AC input and output matches data-centre infrastructure
- 10 ft cord length allows flexible rack placement
Metered Zero U Rack PDU
The APC AP7894 is a metered power distribution unit designed for zero U rack mounting. It delivers 5.7 kVA at 208 V AC for server and networking equipment. Data centre operators and IT administrators use it to monitor aggregate load on each circuit.
Zero U form factor and 10 ft cord
The Zero U design mounts vertically along the rack rear, preserving horizontal rack space for compute gear. A 10 ft input cord reaches overhead or under-floor power feeds without slack. Metered readouts show real-time current draw, helping teams balance phases and avoid overloads.
Verify 208 V supply and rack depth
Confirm your facility provides 208 V AC single-phase or three-phase power before ordering. Ensure the rack depth accommodates the vertical chassis and that cord routing reaches the input source. Check that 50/60 Hz output frequency matches connected equipment ratings.
Helstu kostir
- Metered monitoring tracks power usage in real time
- Zero U vertical mounting saves horizontal rack space
- 7 kVA capacity supports high-density equipment loads
- 208 V AC input and output matches data-centre infrastructure
- 10 ft cord length allows flexible rack placement
Tæknilýsing
| Brand | APC |
|---|---|
| Model | AP7894 |
| Type | Metered |
| Rack Size | Zero U Rack |
| Input Voltage | 208 V AC |
| Cord Length | 10 ft |
| Output Voltage | 208 V AC |
| Output Frequency | 50/60Hz |
| Sendingarþyngd | 11.34 kg |
| Stærð sendingar | 2134 × 152 × 127 mm |
Spurningar um þessa vöru
What input voltage does the AP7894 require, and what maximum load does that support?
The AP7894 operates on 208 V AC input and is rated for a 5.7 kVA capacity, which caps the total connected load at approximately 5.7 kVA.
What rack mounting style does the Zero U design use, and how much vertical space does it consume?
The Zero U form factor mounts vertically along the side rails of a standard rack, consuming zero horizontal rack units so all U spaces remain free for equipment.
How is the 10 ft input cord connected, and what common mistake should be avoided during installation?
The 10 ft cord terminates in a 208 V AC plug that must match the facility receptacle; the frequent error is forcing an incompatible plug type instead of verifying the outlet configuration first.