NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
Mean Well
Delivers 24 V at 6.5 A (156 W) with active PFC, constant-current limiting, free-air convection cooling and a 5 V/0.3 A standby rail in a 1U low-profile chassis
The Mean Well HRPG-150-24 delivers a regulated 24 V output at 6.5 A for 156 W continuous power. It accepts a universal AC input and includes active power-factor correction. A 5 V standby rail supplies 0.3 A for auxiliary circuits. Cooling relies on free-air convection with no internal fan.
Installers who require remote on/off control or sub-0.5 W no-load draw should choose another model, as this variant omits those features. The unit fits 1U low-profile enclosures and survives 300 VAC surge events for five seconds. Built-in protections cover short circuit, overload, over-voltage and over-temperature.
This specification determines whether the supply matches the load and harmonic requirements of the installation. The constant-current limiting circuit and remote-sense terminals support stable voltage under varying cable lengths. A green LED indicates power-on status.
| Type | AT |
|---|
Mount the 1U low-profile unit with the convection vents facing open space; the common mistake is blocking the top or bottom airflow gaps with cables or a chassis panel, which stops the free-air cooling from working.
No scheduled maintenance is required; the only replaceable item is the internal fan-less thermal path — if dust builds up on the heatsink fins after years of use, clean it with compressed air to keep convection effective.
The over-temperature protection triggers first; the built-in constant-current limiting circuit holds output at 6.5A, but sustained full-load heat in a sealed enclosure will trip the thermal shutdown before any electrical limit is reached.
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?