Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

Vertiv

Vertiv AL6D0NHXGNNXLKB 20kVA/18.0kW 208/120VAC LLNG 8min UPS

SKU CH-AN75-538NF MPN AL6D0NHXGNNXLKB

Double-conversion online UPS delivers 20 kVA and 18 kW at 208/120 V with lithium-ion batteries providing 8 minutes at full load or 18 minutes at half load

  • International Version208V
  • Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection4-Wire (L-L-N-G)
  • VA Rating20kVA
  • Watts18kW
  • 20 kVA double-conversion topology protects critical loads from power anomalies
  • Hot-swappable power, battery and control modules enable maintenance without interrupting connected equipment
  • Lithium-ion battery delivers 8 minutes at full load and 18 minutes at half load
  • Wide 200–240 VAC input range with 40–70 Hz auto-sensing suits global deployments
  • Rack/tower form factor fits 38 x 17 x 34 inch footprint for flexible installation

20kVA 18kW lithium-ion UPS

The Vertiv Liebert AL6D0NHXGNNXLKB is a double-conversion online UPS rated at 20kVA and 18.0kW. It accepts 200/100 through 240/120 VAC input with a 4-wire L-L-N-G connection and auto-senses frequency between 40 Hz and 70 Hz. The unit suits critical infrastructure that requires continuous, conditioned power.

Thermals noise and power draw

Operating temperature spans 32°F to 104°F (0°C to 40°C) with humidity tolerance of 0 to 95 percent non-condensing. Double-conversion topology isolates connected loads from input disturbances while maintaining a default 60 Hz output configurable to 50 Hz. Lithium-ion batteries deliver 8 minutes at full load and 18 minutes at half load.

Hot-swappable modules and form factor

Power, battery and control modules are hot-swappable, allowing maintenance without interrupting attached loads. The rack/tower chassis measures 38 by 17 by 34 inches and weighs 484 lbs. Output voltage mirrors the input range, providing 200/100 through 240/120 VAC to matched equipment.

Helstu kostir

  • 20 kVA double-conversion topology protects critical loads from power anomalies
  • Hot-swappable power, battery and control modules enable maintenance without interrupting connected equipment
  • Lithium-ion battery delivers 8 minutes at full load and 18 minutes at half load
  • Wide 200–240 VAC input range with 40–70 Hz auto-sensing suits global deployments
  • Rack/tower form factor fits 38 x 17 x 34 inch footprint for flexible installation

Tæknilýsing

BrandVertiv
SeriesLiebert
ModelAL6D0NHXGNNXLKB
International Version208V
Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection4-Wire (L-L-N-G)
VA Rating20kVA
Watts18kW
Output Voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeLithium Ion
Battery Run TimeFull Load: 8 mins.
Half Load: 18 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions38" x 17" x 34"
Weight484 lbs.
Sendingarþyngd219.54 kg
Stærð sendingar965 × 965 × 432 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

How do I install the 4-wire L-L-N-G input connection on this 20kVA UPS, and what step is most often missed?

Connect the four conductors — two lines, neutral and ground — to the matching terminals, then verify phase rotation with a meter before closing the breaker; the step most often missed is confirming the neutral-to-ground bond matches site wiring.

What maintenance will the lithium-ion battery need and when should I plan replacement?

The lithium-ion cells require no scheduled fluid checks; plan replacement when runtime at full load drops below the rated 8 minutes or after the manufacturer’s design-life threshold, typically 10 to 15 years in 0°C–40°C ambient.

What limit appears first when this 18.0 kW double-conversion UPS runs continuously at full load?

The 8-minute battery runtime at 18.0 kW is the first hard limit; after that the inverter shuts down unless utility power returns or an external generator takes over.