Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

Vertiv

Vertiv Liebert AS5A0NCUGNNXLKB 5 kVA UPS

SKU CH-DWWD-N2JYN MPN AS5A0NCUGNNXLKB

A 5 kVA online double-conversion UPS delivering 4.5 kW with five minutes full-load runtime, scalable to 15 kVA N+1 redundancy in a rack/tower chassis

  • International Version208V
  • Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection4-Wire (L-L-N-G)
  • VA Rating5 kVA
  • Watts4.5 kW
  • Scalable to 15 kVA for growing power demands
  • Online double-conversion topology delivers clean 4.5 kW output
  • Five minutes runtime at full load protects critical equipment
  • Rack or tower form factor fits diverse installations
  • Factory-fitted SNMP card enables remote monitoring

Scalable 5 kVA Double-Conversion UPS

The Vertiv Liebert AS5A0NCUGNNXLKB is a new online double-conversion UPS rated at 5 kVA and 4.5 kW. It accepts 200/100 to 240/120 VAC split-phase input and provides matching output voltages. The unit is scalable to 15 kVA in an N+1 redundant configuration and includes a factory-installed SNMP/web card for network management.

Modular Rack-Tower for Mission-Critical Rooms

This UPS suits computer rooms and mission-critical equipment that need continuous power conditioning and short-duration battery ride-through. It operates from 0°C to 40°C in 0 to 95% non-condensing humidity. Buyers who need longer battery autonomy or a different voltage architecture should look at other solutions.

Five-Minute Full-Load Runtime

At full load the internal VRLA batteries deliver 5 minutes of runtime, extending to 15 minutes at half load. The 4-wire hard-wire input connection and configurable 50/60 Hz output frequency complete the key installation parameters.

Helstu kostir

  • Scalable to 15 kVA for growing power demands
  • Online double-conversion topology delivers clean 4.5 kW output
  • Five minutes runtime at full load protects critical equipment
  • Rack or tower form factor fits diverse installations
  • Factory-fitted SNMP card enables remote monitoring

Tæknilýsing

BrandVertiv
SeriesLiebert
ModelAS5A0NCUGNNXLKB
International Version208V
Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection4-Wire (L-L-N-G)
VA Rating5 kVA
Watts4.5 kW
Output Voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 5 mins.
Half Load: 15 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions27" x 17" x 32"
Weight375 lbs.
Sendingarþyngd170.10 kg
Stærð sendingar813 × 813 × 432 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What 4-wire input connection does the UPS require for its 208/120 VAC split-phase supply?

The unit needs a hard-wired 4-wire feed (L-L-N-G) matching the 200/100 to 240/120 VAC input range and 40-70 Hz auto-sensing frequency.

Can the Liebert APS 5 kVA share a 208/120 VAC split-phase bus with older 208 V single-phase loads?

Yes, its output is configurable to 208/120 VAC split-phase at 50 or 60 Hz, so legacy 208 V single-phase equipment can be fed from one leg while the neutral supports 120 V circuits.

How do I confirm the UPS is delivering 4.5 kW to my rack after installation?

The front LCD status display shows real-time output voltage, frequency and load percentage; verify the load reading matches your 4.5 kW design target and that output voltage sits at the configured 208/120 VAC setting.