Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

Vertiv

Vertiv Liebert AS4A0NCUGNNXLKB 5kVA 208V UPS 5min runtime

SKU CH-CGV6-Q64NQ MPN AS4A0NCUGNNXLKB

5 kVA online double-conversion UPS with 5-minute full-load runtime, scalable to 20 kVA N+1, 208 V single-phase input, hot-swappable VRLA batteries, LCD status display, factory-fitted SNMP card.

  • International Version208V
  • Input Voltage Range200/208/220/230/240 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection3-Wire (L-L-G)
  • VA Rating5 kVA
  • Watts4.5 kW
  • 5 kVA scalable to 20 kVA N+1 for mission-critical growth
  • Online double conversion delivers clean 4.5 kW output
  • 5 minutes full-load runtime, 14 minutes at half load
  • Hot-swappable VRLA batteries enable maintenance without downtime
  • LCD status display plus factory-fitted SNMP webcard for remote monitoring

Scalable 5 kVA UPS for mission-critical loads

This Vertiv Liebert UPS delivers 5 kVA and 4.5 kW of online double-conversion power in a rack or tower form factor. It ships new with a factory-installed SNMP web card for network management. The system scales to 20 kVA in an N+1 redundant configuration, protecting mission-critical equipment. Hot-swappable modules allow maintenance without downtime.

Input range and hard-wired installation limits

The unit accepts 200 to 240 VAC across a 40 to 70 Hz auto-sensing window, locking to 60 Hz output by default with 50 Hz user-configurable. It requires a 3-wire L-L-G hard-wired connection, so no plug-and-play cordset is provided. Operation is rated from 32 to 104 Fahrenheit with humidity up to 95 percent non-condensing. These constraints define the electrical and environmental envelope.

Runtime headroom at full and half load

Valve-regulated lead-acid batteries provide 5 minutes at the full 4.5 kW load and 14 minutes at half load. This window suits orderly shutdown or generator start sequences rather than extended ride-through. The 635-pound chassis measures 49 by 17 by 34 inches, demanding substantial floor or rack space. Buyers needing longer autonomy or lighter weight should evaluate additional battery cabinets or alternative topologies.

Helstu kostir

  • 5 kVA scalable to 20 kVA N+1 for mission-critical growth
  • Online double conversion delivers clean 4.5 kW output
  • 5 minutes full-load runtime, 14 minutes at half load
  • Hot-swappable VRLA batteries enable maintenance without downtime
  • LCD status display plus factory-fitted SNMP webcard for remote monitoring

Tæknilýsing

BrandVertiv
SeriesLiebert
ModelAS4A0NCUGNNXLKB
International Version208V
Input Voltage Range200/208/220/230/240 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection3-Wire (L-L-G)
VA Rating5 kVA
Watts4.5 kW
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 5 mins.
Half Load: 14 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions49" x 17" x 34"
Weight635 lbs.
Sendingarþyngd288.03 kg
Stærð sendingar1245 × 1245 × 432 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

Should I choose the 5 kVA or the 20 kVA scalable version for my load?

This unit ships as a 5 kVA, 4.5 kW module; you can add up to three more hot-swappable modules later to reach 20 kVA N+1 redundancy.

What does the 5-minute full-load runtime mean for my 4.5 kW equipment?

At the full 4.5 kW draw the internal VRLA batteries will keep the load running for 5 minutes; at half load the same batteries last 14 minutes.

How does the 208 V single-phase 3-wire input affect installation?

The UPS requires a hard-wired 3-wire L-L-G feed at 200–240 VAC and auto-senses 40–70 Hz, so no separate neutral conductor is needed.