Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

Vertiv

Vertiv AS4C0NCWGNNXLKB 15 kVA UPS 208V 13.5 kW 15 min runtime

SKU CH-6W9J-JK9ZE MPN AS4C0NCWGNNXLKB

A 15 kVA online double-conversion UPS delivering 13.5 kW with 15 minutes full-load runtime in a rack/tower form factor

  • International Version208V
  • Input Voltage Range200/208/220/230/240 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection3-Wire (L-L-G)
  • VA Rating15 kVA
  • Watts13.5 kW
  • 15 kVA online double-conversion topology protects critical loads
  • Scalable to 20 kVA with N+1 redundancy for growth
  • 15 minutes full-load runtime from VRLA batteries
  • 200–240 VAC auto-sensing input handles unstable power
  • Rack or tower form factor fits diverse installations

15 kVA 208V modular UPS

This Vertiv Liebert UPS delivers 15 kVA and 13.5 kW through online double-conversion topology. The 208 V single-phase design scales to 20 kVA with N+1 redundancy for growing server rooms. A factory-fitted SNMP/Webcard enables remote monitoring from day one. Rack or tower mounting suits both data-centre rows and office corners.

Rack or tower install with 3-wire input

The unit accepts 200 to 240 VAC on a 3-wire L-L-G connection and auto-senses 40 Hz to 70 Hz input frequency. At 825 lbs the cabinet needs mechanical lift equipment and a rated floor; two-person positioning is not sufficient. Output frequency defaults to 60 Hz and is user-configurable to 50 Hz. LCD status indicators give immediate local feedback during commissioning.

15 min full-load runtime with VRLA battery

Valve-regulated lead-acid cells provide 15 minutes at 13.5 kW and 39 minutes at half load. Runtime drops to 5 minutes if the inverter is loaded to the full 15 kVA apparent-power rating. Operating envelope spans 32 °F to 104 °F with humidity up to 95 % non-condensing. Sites needing longer hold-up or lithium chemistry must look elsewhere.

Helstu kostir

  • 15 kVA online double-conversion topology protects critical loads
  • Scalable to 20 kVA with N+1 redundancy for growth
  • 15 minutes full-load runtime from VRLA batteries
  • 200–240 VAC auto-sensing input handles unstable power
  • Rack or tower form factor fits diverse installations

Tæknilýsing

BrandVertiv
SeriesLiebert
ModelAS4C0NCWGNNXLKB
International Version208V
Input Voltage Range200/208/220/230/240 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection3-Wire (L-L-G)
VA Rating15 kVA
Watts13.5 kW
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 5 mins.
Half Load: 14 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions49" x 17" x 34"
Weight825 lbs.
Sendingarþyngd374.21 kg
Stærð sendingar1245 × 1245 × 432 mm

Aðrar útgáfur af þessari vöru

5 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

How can I confirm the unit is operating normally after installation?

The front LCD status indicators show real-time input voltage, output frequency, load percentage and battery health so you can verify the 13.5 kW output and 208 V operation at a glance.

What ships with the UPS and what must be purchased separately?

The rack/tower chassis with factory-installed SNMP/Webcard and internal VRLA batteries for 15-minute full-load runtime are included; input/output power cables, external battery cabinets and rail kits are not.

Should I choose the 15 kVA model or the scalable 20 kVA N+1 configuration?

Select the 15 kVA version if your present load is near 13.5 kW; choose the scalable 20 kVA N+1 frame when you plan to add power modules later for redundancy or growth.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.