Priimame kriptovaliutą — taip monetos, kurias turite, gali nupirkti tikrą techniką.Mokėkite kriptovaliuta, išleiskite ją tikrai technikai. Nemokamas apdraustas pristatymas visame pasaulyje virš 399 $. Paprastos, be žymų siuntos dėžės, siunčiamos iš Vokietijos.Nemokamas apdraustas pristatymas virš 399 $. Jūsų kursas fiksuojamas 30 minučių, kai tik prasideda atsiskaitymas.Kursas fiksuojamas 30 minučių. Kiekvienas gaminys užplombuotas, jo serijos numeris patikrintas, ir jam taikoma 24 mėnesių garantija.Užplombuota, 24 mėnesių garantija.
myVolts
DIN-rail 24 V AC-DC supply delivers 120 W with overload, over-voltage, short-circuit and over-current protection
This myVolts unit converts 100 to 240 V AC into a stable 24 V DC output rated at 120 W and 5 A. It mounts on a standard 35 mm DIN rail and operates from -10 °C to 60 °C with 85 % typical efficiency. Built-in overload, over-voltage, short-circuit and over-current protection shuts the output down automatically and resets once the fault clears. The compact, ventilated metal housing dissipates heat without a fan.
Control-panel builders and automation engineers who need a single-phase 24 V 5 A supply for PLCs, sensors or relay banks will find the voltage accuracy of ±1 % and 200 mV ripple suitable. Buyers who require higher output current, redundant operation or a different output voltage should look at other models. The fixed 60 Hz input frequency also means the unit is not suited for variable-frequency sources.
The 120 W rating sets the maximum load the supply can deliver continuously at 24 V. If the connected equipment draws more than 5 A the protection will trip, so total load must stay at or below this figure. The 35 mm rail mounting and 100 to 240 V auto-ranging input are fixed mechanical and electrical constraints that also determine suitability.
| Type | AT |
|---|
Clip the unit onto the rail until the latch clicks, then verify the housing is fully seated with no gap; the missed step is confirming the latch has locked rather than resting loose.
No scheduled maintenance is required; keep the ventilation slots clear of dust so the hollow-shell convection cooling stays effective and the automatic protection circuits remain responsive.
The supply delivers up to 5A continuously; sustained draw at that level is the first limit, triggering overload protection if exceeded while the unit operates within the -10 to 60°C range.
Taip pat šiame skyriuje
Ta pati lentyna, tas pats atsiskaitymas — aštuonios monetos ir 30 minučių fiksuotas kursas.
Tai, kuo mokate, ir valiuta, kuria matote kainas.
Išsiunčiama iš Jūsų piniginės atsiskaitant
Tik rodoma — katalogo kainos nurodytos doleriais
Tokios valiutos nerasta.
Pasirinkite kalbą, kuria Jums kalbės svetainė.
Pirmą kartą čia?
Jau turite paskyrą?
Automatinio atstatymo nėra: ši parduotuvė nesiunčia jokių el. laiškų, todėl nėra jokios vienkartinės nuorodos, kurios būtų galima paprašyti. Palikite adresą paskyroje, ir juo bus pasirūpinta rankiniu būdu.
Prašymas užfiksuotas
Į Jūsų pašto dėžutę niekas nekeliauja — ši parduotuvė apskritai nesiunčia jokių el. laiškų. Šiuos prašymus kažkas peržiūri rankiniu būdu.
Prisiminėte?