Sprejemamo kriptovalute — tako lahko sredstva, ki jih imate, kupijo pravo strojno opremo.Plačajte v kriptovaluti, zapravite jo za pravo strojno opremo. Brezplačna zavarovana dostava po vsem svetu nad 399 $. Nevtralni kartoni brez znamke, poslani iz Nemčije.Brezplačna zavarovana dostava nad 399 $. Vaš tečaj je zaklenjen za 30 minut, takoj ko se odpre blagajna.Tečaj zaklenjen 30 minut. Vsak izdelek je zapečaten, njegova serijska številka preverjena, in krit z 24-mesečno garancijo.Zapečateno, 24-mesečna garancija.
myVolts
DIN-rail 24 V AC-DC supply delivers 120 W with overload, over-voltage, short-circuit and over-current protection
This myVolts unit converts 100 to 240 V AC into a stable 24 V DC output rated at 120 W and 5 A. It mounts on a standard 35 mm DIN rail and operates from -10 °C to 60 °C with 85 % typical efficiency. Built-in overload, over-voltage, short-circuit and over-current protection shuts the output down automatically and resets once the fault clears. The compact, ventilated metal housing dissipates heat without a fan.
Control-panel builders and automation engineers who need a single-phase 24 V 5 A supply for PLCs, sensors or relay banks will find the voltage accuracy of ±1 % and 200 mV ripple suitable. Buyers who require higher output current, redundant operation or a different output voltage should look at other models. The fixed 60 Hz input frequency also means the unit is not suited for variable-frequency sources.
The 120 W rating sets the maximum load the supply can deliver continuously at 24 V. If the connected equipment draws more than 5 A the protection will trip, so total load must stay at or below this figure. The 35 mm rail mounting and 100 to 240 V auto-ranging input are fixed mechanical and electrical constraints that also determine suitability.
| Type | AT |
|---|
Clip the unit onto the rail until the latch clicks, then verify the housing is fully seated with no gap; the missed step is confirming the latch has locked rather than resting loose.
No scheduled maintenance is required; keep the ventilation slots clear of dust so the hollow-shell convection cooling stays effective and the automatic protection circuits remain responsive.
The supply delivers up to 5A continuously; sustained draw at that level is the first limit, triggering overload protection if exceeded while the unit operates within the -10 to 60°C range.
Tudi v tem oddelku
Ista polica, ista blagajna — osem kriptovalut in 30-minutni zaklep tečaja.
V čem plačujete in v čem berete cene.
Poslano iz Vaše denarnice ob blagajni
Samo za prikaz — katalog je cenovno izražen v dolarjih
Nobena valuta ne ustreza.
Izberite jezik, v katerem Vam govori spletna stran.
Prvič tu?
Že imate račun?
Samodejne ponastavitve ni: ta trgovina ne pošilja e-pošte, zato ni enkratne povezave, ki bi jo lahko zahtevali. Pustite naslov na računu — nekdo ga bo obravnaval ročno.
Zahteva zabeležena
V Vašo elektronsko pošto ne prihaja nič — ta trgovina ne pošilja nobene e-pošte. Zahteve nekdo obravnava ročno.
Ste se spomnili?