Vi tar emot kryptovaluta — så att kryptot du äger kan köpa riktig hårdvara.Betala med krypto, använd det till riktig hårdvara. Fri, försäkrad frakt över hela världen vid köp över 399 $. Neutrala, omärkta ytterkartonger, skickade från Tyskland.Fri, försäkrad frakt över 399 $. Din kurs låses i 30 minuter så snart kassan öppnas.Kursen låst i 30 minuter. Varje artikel är förseglad, har kontrollerat serienummer och täcks av 24 månaders garanti.Förseglad, 24 månaders garanti.
myVolts
DIN-rail 24 V AC-DC supply delivers 120 W with overload, over-voltage, short-circuit and over-current protection
This myVolts unit converts 100 to 240 V AC into a stable 24 V DC output rated at 120 W and 5 A. It mounts on a standard 35 mm DIN rail and operates from -10 °C to 60 °C with 85 % typical efficiency. Built-in overload, over-voltage, short-circuit and over-current protection shuts the output down automatically and resets once the fault clears. The compact, ventilated metal housing dissipates heat without a fan.
Control-panel builders and automation engineers who need a single-phase 24 V 5 A supply for PLCs, sensors or relay banks will find the voltage accuracy of ±1 % and 200 mV ripple suitable. Buyers who require higher output current, redundant operation or a different output voltage should look at other models. The fixed 60 Hz input frequency also means the unit is not suited for variable-frequency sources.
The 120 W rating sets the maximum load the supply can deliver continuously at 24 V. If the connected equipment draws more than 5 A the protection will trip, so total load must stay at or below this figure. The 35 mm rail mounting and 100 to 240 V auto-ranging input are fixed mechanical and electrical constraints that also determine suitability.
| Type | AT |
|---|
Clip the unit onto the rail until the latch clicks, then verify the housing is fully seated with no gap; the missed step is confirming the latch has locked rather than resting loose.
No scheduled maintenance is required; keep the ventilation slots clear of dust so the hollow-shell convection cooling stays effective and the automatic protection circuits remain responsive.
The supply delivers up to 5A continuously; sustained draw at that level is the first limit, triggering overload protection if exceeded while the unit operates within the -10 to 60°C range.
Även i den här avdelningen
Samma hylla, samma kassa — åtta mynt och ett 30-minuters kurslås.
Det du betalar med, och det du ser priserna i.
Skickas från din plånbok i kassan
Endast visning — katalogen är prissatt i US-dollar
Ingen valuta matchar.
Välj det språk du vill att webbplatsen ska visas på.
Ny här?
Har du redan ett konto?
Det finns ingen automatisk återställning: den här butiken skickar inga e-postmeddelanden, så det finns ingen engångslänk att begära. Lämna adressen kopplad till kontot, så hanteras den för hand.
Förfrågan noterad
Inget är på väg till din inkorg — den här butiken skickar aldrig e-post. Någon tar hand om detta manuellt.
Kom du på det?