Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.
myVolts
DIN-rail 24 V AC-DC supply delivers 120 W with overload, over-voltage, short-circuit and over-current protection
This myVolts unit converts 100 to 240 V AC into a stable 24 V DC output rated at 120 W and 5 A. It mounts on a standard 35 mm DIN rail and operates from -10 °C to 60 °C with 85 % typical efficiency. Built-in overload, over-voltage, short-circuit and over-current protection shuts the output down automatically and resets once the fault clears. The compact, ventilated metal housing dissipates heat without a fan.
Control-panel builders and automation engineers who need a single-phase 24 V 5 A supply for PLCs, sensors or relay banks will find the voltage accuracy of ±1 % and 200 mV ripple suitable. Buyers who require higher output current, redundant operation or a different output voltage should look at other models. The fixed 60 Hz input frequency also means the unit is not suited for variable-frequency sources.
The 120 W rating sets the maximum load the supply can deliver continuously at 24 V. If the connected equipment draws more than 5 A the protection will trip, so total load must stay at or below this figure. The 35 mm rail mounting and 100 to 240 V auto-ranging input are fixed mechanical and electrical constraints that also determine suitability.
| Type | AT |
|---|
Clip the unit onto the rail until the latch clicks, then verify the housing is fully seated with no gap; the missed step is confirming the latch has locked rather than resting loose.
No scheduled maintenance is required; keep the ventilation slots clear of dust so the hollow-shell convection cooling stays effective and the automatic protection circuits remain responsive.
The supply delivers up to 5A continuously; sustained draw at that level is the first limit, triggering overload protection if exceeded while the unit operates within the -10 to 60°C range.
Ook in deze afdeling
Dezelfde afdeling, dezelfde kassa — acht munten en een koers die 30 minuten vaststaat.
Waarmee u betaalt, en waarin u de prijzen leest.
Verzonden vanuit uw wallet bij het afrekenen
Alleen ter weergave — de catalogus is geprijsd in USD
Geen valuta gevonden.
Kies de taal waarin de site met u spreekt.
Nieuw hier?
Al een account?
Er is geen automatisch herstel: deze winkel verstuurt geen e-mail, dus er is geen eenmalige link om aan te vragen. Laat het adres op het account achter en het wordt handmatig opgepakt.
Verzoek genoteerd
Er is niets onderweg naar uw inbox — deze winkel verstuurt helemaal geen e-mail. Iemand pakt dit handmatig op.
Weet u het weer?