JacobsParts Inc. FP5139 100W DC Boost Step-up Converter
- 100 W
Nous acceptons la cryptomonnaie — les cryptos que vous détenez peuvent ainsi acheter du matériel réel.Payez en crypto, dépensez-la en matériel réel. Livraison assurée offerte partout dans le monde au-delà de 399 $. Cartons neutres, sans marque, expédiés depuis l’Allemagne.Livraison assurée offerte au-delà de 399 $. Votre taux est bloqué pendant 30 minutes dès l’ouverture de la caisse.Taux bloqué 30 minutes. Chaque article est scellé, son numéro de série est vérifié, et il est couvert par une garantie de 24 mois.Scellé, garanti 24 mois.
myVolts
DIN-rail 24 V AC-DC supply delivers 120 W with overload, over-voltage, short-circuit and over-current protection
This myVolts unit converts 100 to 240 V AC into a stable 24 V DC output rated at 120 W and 5 A. It mounts on a standard 35 mm DIN rail and operates from -10 °C to 60 °C with 85 % typical efficiency. Built-in overload, over-voltage, short-circuit and over-current protection shuts the output down automatically and resets once the fault clears. The compact, ventilated metal housing dissipates heat without a fan.
Control-panel builders and automation engineers who need a single-phase 24 V 5 A supply for PLCs, sensors or relay banks will find the voltage accuracy of ±1 % and 200 mV ripple suitable. Buyers who require higher output current, redundant operation or a different output voltage should look at other models. The fixed 60 Hz input frequency also means the unit is not suited for variable-frequency sources.
The 120 W rating sets the maximum load the supply can deliver continuously at 24 V. If the connected equipment draws more than 5 A the protection will trip, so total load must stay at or below this figure. The 35 mm rail mounting and 100 to 240 V auto-ranging input are fixed mechanical and electrical constraints that also determine suitability.
| Type | AT |
|---|
Clip the unit onto the rail until the latch clicks, then verify the housing is fully seated with no gap; the missed step is confirming the latch has locked rather than resting loose.
No scheduled maintenance is required; keep the ventilation slots clear of dust so the hollow-shell convection cooling stays effective and the automatic protection circuits remain responsive.
The supply delivers up to 5A continuously; sustained draw at that level is the first limit, triggering overload protection if exceeded while the unit operates within the -10 to 60°C range.
Également dans ce rayon
Même rayon, même caisse — huit monnaies et un taux bloqué 30 minutes.
Ce que vous envoyez, et ce dans quoi vous lisez les prix.
Envoyé depuis votre portefeuille à la caisse
Affichage seul — le catalogue est libellé en dollars
Aucune monnaie ne correspond.
Choisissez la langue dans laquelle le site vous parle.
Première visite ?
Vous avez déjà un compte ?
Il n’y a pas de réinitialisation automatique : cette boutique n’envoie aucun e-mail, il n’existe donc aucun lien à usage unique à demander. Laissez l’adresse sur le compte, elle sera traitée à la main.
Demande enregistrée
Rien n’arrivera dans votre boîte de réception — cette boutique n’envoie aucun e-mail. Quelqu’un s’en occupe à la main.
Vous l’avez retrouvé ?