Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.
HP
A UPS management module that provides three-phase DirectFlow power distribution at 30A and 400V-415V with IEC309 input and output connections
The HP AF478A is a DirectFlow UPS management module rated for 30 A at 400 V to 415 V three-phase input. It integrates charger, inverter and active filter functions into a single compact unit for HP servers and storage. The module uses IEC 309 connectors for both input and output. It is designed to work with part numbers AF478A and G9Y75A.
DirectFlow technology removes the active front-end AC/DC conversion steps, delivering efficiency exceeding 99 %. Integrated active current correction keeps the power factor close to unity even at low loads. The design reduces both physical size and cost compared with traditional UPS architectures. Clean power output helps lower overall energy costs.
This module replaces a conventional UPS power management unit in an existing DirectFlow rack system. It is suited for installations that need a high-density 12 kW backup solution without the footprint of legacy equipment. Buyers who require a different current rating or single-phase operation should look elsewhere. The jump is worthwhile when expanding capacity within the same DirectFlow chassis.
| Brand | HP |
|---|---|
| Model | AF478A |
| Type | UPS management module |
| Features | Three Phase,DirectFlow |
Mount the module in the DirectFlow UPS frame, connect the IEC 309 three-phase input and output cables at 400 V to 415 V, then secure the 30 A circuit-breaker linkage; the step often missed is torquing the IEC 309 terminals to the specified value before energising.
Plan to replace the internal battery packs that supply the DirectFlow UPS when runtime drops below requirements; the management module itself has no user-serviceable parts, so only the battery trays need periodic swap-out.
The 30 A three-phase input rating at 400 V to 415 V is the first hard limit; exceeding it trips the IEC 309 breaker, so sustained draw must stay within the 30 A per phase envelope.
Arī šajā sadaļā
Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.
Kriptovalūta, kurā maksājat, un valūta, kurā redzat cenas.
Nosūtīts no Jūsu maciņa, noformējot pasūtījumu
Tikai informatīvi — katalogā cenas norādītas ASV dolāros
Neviena valūta neatbilst.
Izvēlieties valodu, kurā vietne sarunājas ar Jums.
Pirmo reizi šeit?
Jau ir konts?
Automātiskas atiestatīšanas nav: šis veikals nesūta e-pastus, tāpēc nav arī vienreizējas saites, ko pieprasīt. Atstājiet adresi kontā, un tā tiks apstrādāta manuāli.
Pieprasījums saņemts
Uz Jūsu e-pastu nekas neatnāks — šis veikals vispār nesūta e-pastus. Kāds šos pieprasījumus apstrādā manuāli.
Atcerējāties?