NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
HP
A UPS management module that provides three-phase DirectFlow power distribution at 30A and 400V-415V with IEC309 input and output connections
The HP AF478A is a DirectFlow UPS management module rated for 30 A at 400 V to 415 V three-phase input. It integrates charger, inverter and active filter functions into a single compact unit for HP servers and storage. The module uses IEC 309 connectors for both input and output. It is designed to work with part numbers AF478A and G9Y75A.
DirectFlow technology removes the active front-end AC/DC conversion steps, delivering efficiency exceeding 99 %. Integrated active current correction keeps the power factor close to unity even at low loads. The design reduces both physical size and cost compared with traditional UPS architectures. Clean power output helps lower overall energy costs.
This module replaces a conventional UPS power management unit in an existing DirectFlow rack system. It is suited for installations that need a high-density 12 kW backup solution without the footprint of legacy equipment. Buyers who require a different current rating or single-phase operation should look elsewhere. The jump is worthwhile when expanding capacity within the same DirectFlow chassis.
| Brand | HP |
|---|---|
| Model | AF478A |
| Type | UPS management module |
| Features | Three Phase,DirectFlow |
Mount the module in the DirectFlow UPS frame, connect the IEC 309 three-phase input and output cables at 400 V to 415 V, then secure the 30 A circuit-breaker linkage; the step often missed is torquing the IEC 309 terminals to the specified value before energising.
Plan to replace the internal battery packs that supply the DirectFlow UPS when runtime drops below requirements; the management module itself has no user-serviceable parts, so only the battery trays need periodic swap-out.
The 30 A three-phase input rating at 400 V to 415 V is the first hard limit; exceeding it trips the IEC 309 breaker, so sustained draw must stay within the 30 A per phase envelope.
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?